Environment - simulationEnvironment: startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=1000 stepSize=7.2 Regular simulation: ./TAeZoSysPro_TAeZoSysPro.HeatTransfer.Examples.Room_with_wood_burner -abortSlowSimulation -alarm=240 -s gbode -gbm=radauIIA3 -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_STDOUT | info | iteration to converge on Fview: 8 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:21:3-21:129:writable] | | | | the Rayleigh number > 10^12 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ceiling_ASHRAE.mo:54:5-54:128:writable] | | | | the Rayleigh number <10^5 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:48:5-48:136:writable] | | | | the Rayleigh number >1.5*10^9 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ceiling_ASHRAE.mo:49:5-49:136:writable] | | | | the Rayleigh number >1.5*10^9 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/ground_ASHRAE.mo:54:5-54:129:writable] | | | | the Rayleigh number >10^9 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:20:3-20:157:writable] | | | | the Rayleigh number < 10^9 is out of the range of the correlation. => Correlation extrapolated LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/BasesClasses/FreeConvection_dT_decoupled.mo:20:3-20:70:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((wood_burner.convection_emitter.T_mean >= 273.15 and wood_burner.convection_emitter.T_mean <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= wood_burner.convection_emitter.T_mean <= 373.15, has value: 563.628" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 7.1905e-05s [ 0.4%] pre-initialization | | | | | | 0.000540799s [ 3.1%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 2.685e-06s [ 0.0%] creating output-file | | | | | | 0s [ 0.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0168133s [ 96.5%] simulation | | | | | | 0.0174287s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 69 steps taken | | | | | | 350 calls of functionODE | | | | | | 10 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.