Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./Buildings_13_Buildings.DHC.Plants.Combined.Subsystems.Validation.MultiplePumpsSpeed -abortSlowSimulation -alarm=240 -s gbode -gbm=radauIIA3 -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 100.000000 | | | | ((pum2.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum2.etaHyd, has value: -8.06618e-11" LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 1000.000000 | | | | ((pum.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pum.etaHyd, has value: -9.79111e-40" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 1000.000000 | | | | ((pum1.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum1.etaHyd, has value: -4.3979e-39" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 0.000141466s [ 1.0%] pre-initialization | | | | | | 0.000489252s [ 3.6%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 3.247e-06s [ 0.0%] creating output-file | | | | | | 0.000448756s [ 3.3%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0123958s [ 92.0%] simulation | | | | | | 0.0134786s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 6 time events | | | | | solver: gbode | | | | | | 82 steps taken | | | | | | 455 calls of functionODE | | | | | | 25 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 16 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.