Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-08 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator -abortSlowSimulation -alarm=240 -s gbode -gbm=radauIIA3 -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaPumSou.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in AirToWater2D_OneRoomRadiator.pumHeaPumSou: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/HeatPumps/ModularReversible/TableData2D.mo:78:3-83:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(heaPum.scaFacHea - heaPum.scaFacCoo) / heaPum.scaFacHea < heaPum.limWarSca)) --> "In AirToWater2D_OneRoomRadiator.heaPum: Scaling factors for heating and cooling | | | | operation differ by -17.4444 %. The simulated nominal heating and cooling | | | | capacities may not be realistic for a single device" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 7.0884e-05s [ 0.1%] pre-initialization | | | | | | 0.0197789s [ 24.3%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 2.184e-06s [ 0.0%] creating output-file | | | | | | 0.00215276s [ 2.6%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0595502s [ 73.0%] simulation | | | | | | 0.0815549s [100.0%] total | | | | | events | | | | | | 256 state events | | | | | | 4 time events | | | | | solver: gbode | | | | | | 3427 steps taken | | | | | | 14878 calls of functionODE | | | | | | 277 evaluations of jacobian | | | | | | 12 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.