Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr AES_AES.ProcessComponents.Thermal.HVAC.StratifiedTank_2zones.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0009556/0.0009556, allocations: 80.88 kB / 20.74 MB, free: 3.59 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001807/0.001807, allocations: 177 kB / 24.16 MB, free: 176 kB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.009/1.009, allocations: 177.2 MB / 204.6 MB, free: 5.465 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/package.mo): time 0.08958/0.08958, allocations: 18.14 MB / 279.2 MB, free: 11.18 MB / 266.7 MB " [Timeout remaining time 180] Using package AES with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(AES.ProcessComponents.Thermal.HVAC.StratifiedTank_2zones,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="AES_AES.ProcessComponents.Thermal.HVAC.StratifiedTank_2zones") translateModel(AES.ProcessComponents.Thermal.HVAC.StratifiedTank_2zones,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="AES_AES.ProcessComponents.Thermal.HVAC.StratifiedTank_2zones") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 2.304e-06/2.304e-06, allocations: 0 / 304.6 MB, free: 0.5039 MB / 266.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.804e-05/3.035e-05, allocations: 4.562 kB / 304.6 MB, free: 0.5 MB / 266.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/ProcessComponents/Thermal/HVAC/StratifiedTank_2zones.mo:4:3-4:45:writable] Error: The model can't be instantiated due to top-level outer element 'system', it may only be used as part of a simulation model. Notification: Performance of FrontEnd: time 0.003515/0.003546, allocations: 1.661 MB / 306.2 MB, free: 15.38 MB / 282.7 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 1.8369341348297894]