Environment - simulationEnvironment: startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.01 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.HeatExchangers.Tests.Evaporator -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0282993s reading init.xml | | | | | | 0.00305169s reading info.xml | | | | | | 0.00564127s [ 0.8%] pre-initialization | | | | | | 0.00224812s [ 0.3%] initialization | | | | | | 0.000369505s [ 0.1%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00199963s [ 0.3%] creating output-file | | | | | | -7.14684e-22s [ -0.0%] event-handling | | | | | | 0.00247847s [ 0.3%] overhead | | | | | | 0.699765s [ 98.2%] simulation | | | | | | 0.712509s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: gbode | | | | | | 88 steps taken | | | | | | 559 calls of functionODE | | | | | | 18 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 1 convergence test failures | | | | | | 0.147894s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.