Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.02 Regular simulation: ./ThermofluidStream_ThermofluidStream.FlowControl.Tests.ValveReferenceValues -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/BasicControlValve.mo:40:6-40:225:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(1e-5 * dp_ref.dp_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.dp_ref": dp_ref must remain at its default value of 1 bar when using Kvs, Cvs_US, or Cvs_UK. Remove the dp_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/BasicControlValve.mo:41:6-41:234:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(0.001 * rho_ref.rho_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.rho_ref": rho_ref must remain at its default value of 1000 kg/m3 when using Kvs, Cvs_US, or Cvs_UK. Remove the rho_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/SpecificValveType.mo:55:6-55:225:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(1e-5 * dp_ref1.dp_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.dp_ref1": dp_ref must remain at its default value of 1 bar when using Kvs, Cvs_US, or Cvs_UK. Remove the dp_ref modifier." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/SpecificValveType.mo:56:6-56:234:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(0.001 * rho_ref1.rho_ref - 1.0) <= 2.220446049250313e-16)) --> "In "ValveReferenceValues.rho_ref1": rho_ref must remain at its default value of 1000 kg/m3 when using Kvs, Cvs_US, or Cvs_UK. Remove the rho_ref modifier." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0112967s reading init.xml | | | | | | 0.0011019s reading info.xml | | | | | | 0.0234475s [ 79.5%] pre-initialization | | | | | | 0.000768966s [ 2.6%] initialization | | | | | | 9.609e-06s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000756541s [ 2.6%] creating output-file | | | | | | 2.81e-06s [ 0.0%] event-handling | | | | | | 0.000562224s [ 1.9%] overhead | | | | | | 0.00393689s [ 13.4%] simulation | | | | | | 0.0294845s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 2 time events | | | | | solver: gbode | | | | | | 111 steps taken | | | | | | 916 calls of functionODE | | | | | | 73 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 8 convergence test failures | | | | | | 0.000122497s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.