Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.5742/0.5742, allocations: 111.6 MB / 131.5 MB, free: 4.91 MB / 122.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 2.715e-06/2.715e-06, allocations: 0 / 176.6 MB, free: 8.926 MB / 170.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.132e-05/2.404e-05, allocations: 5.703 kB / 176.6 MB, free: 8.922 MB / 170.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC): time 1.606/1.606, allocations: 364.5 MB / 0.5284 GB, free: 10.94 MB / 459.2 MB Notification: Performance of NFInst.instExpressions: time 0.7496/2.355, allocations: 243.8 MB / 0.7665 GB, free: 4.375 MB / 0.6364 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01515/2.371, allocations: 0.5782 MB / 0.7671 GB, free: 4.375 MB / 0.6364 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:98:3-99:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:100:3-101:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:102:3-103:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:104:3-105:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:115:3-116:133:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:117:3-118:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:119:3-120:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:98:3-99:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:100:3-101:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:102:3-103:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:104:3-105:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:115:3-116:133:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:117:3-118:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:119:3-120:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:77:3-78:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:81:3-82:131:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:83:3-84:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:98:3-99:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:100:3-101:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:102:3-103:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:104:3-105:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:115:3-116:133:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:117:3-118:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:119:3-120:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SinkP.mo:32:3-33:80:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:46:3-47:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:48:3-49:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:52:3-53:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:46:3-47:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:48:3-49:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:52:3-53:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:46:3-47:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:48:3-49:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:52:3-53:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:90:3-91:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:92:3-93:79:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:98:3-99:81:writable] Warning: Connector Cee is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:100:3-101:79:writable] Warning: Connector Cse is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceQ.mo:39:3-40:78:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SinkP.mo:32:3-33:80:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:77:3-78:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:81:3-82:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:83:3-84:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:40:3-41:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:42:3-43:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:40:3-41:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:42:3-43:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:40:3-41:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:42:3-43:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:77:3-78:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:79:3-80:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:81:3-82:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:83:3-84:64:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceQ.mo:39:3-40:78:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0116/2.382, allocations: 6.16 MB / 0.7731 GB, free: 4.355 MB / 0.6364 GB Notification: Performance of NFTyping.typeBindings: time 0.03494/2.417, allocations: 18.99 MB / 0.7917 GB, free: 348 kB / 0.6364 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:470:9-470:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:525:9-525:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:708:9-708:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/Fluid/derDensity_derP_derh.mo:56:5-56:88:writable] Warning: T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:964:9-964:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.06216/2.479, allocations: 36.72 MB / 0.8275 GB, free: 2.27 MB / 0.652 GB Notification: Performance of NFFlatten.flatten: time 0.09517/2.574, allocations: 112.8 MB / 0.9377 GB, free: 8.582 MB / 0.7458 GB Notification: Performance of NFFlatten.resolveConnections: time 0.04323/2.618, allocations: 35.68 MB / 0.9725 GB, free: 6.5 MB / 0.777 GB Notification: Performance of NFEvalConstants.evaluate: time 0.09821/2.716, allocations: 53.42 MB / 1.025 GB, free: 3.422 MB / 0.8239 GB Notification: Performance of NFSimplifyModel.simplify: time 0.3722/3.088, allocations: 35.13 MB / 1.059 GB, free: 103.4 MB / 0.8239 GB Notification: Performance of NFPackage.collectConstants: time 0.03015/3.118, allocations: 7.905 MB / 1.067 GB, free: 103.4 MB / 0.8239 GB Notification: Performance of NFFlatten.collectFunctions: time 0.07678/3.195, allocations: 36.16 MB / 1.102 GB, free: 103.4 MB / 0.8239 GB Notification: Performance of NFScalarize.scalarize: time 0.03649/3.231, allocations: 25.14 MB / 1.127 GB, free: 103.4 MB / 0.8239 GB Notification: Performance of NFVerifyModel.verify: time 0.05577/3.287, allocations: 25.2 MB / 1.151 GB, free: 100.6 MB / 0.8239 GB Notification: Performance of NFConvertDAE.convert: time 0.115/3.402, allocations: 80.7 MB / 1.23 GB, free: 39.49 MB / 0.8239 GB Notification: Performance of FrontEnd - DAE generated: time 6.352e-06/3.402, allocations: 0 / 1.23 GB, free: 39.49 MB / 0.8239 GB Notification: Performance of FrontEnd: time 1.723e-06/3.402, allocations: 0 / 1.23 GB, free: 39.49 MB / 0.8239 GB Notification: Performance of Transformations before backend: time 0.002595/3.405, allocations: 4 kB / 1.23 GB, free: 39.48 MB / 0.8239 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 15109 * Number of variables: 15109 Notification: Performance of Generate backend data structure: time 0.1273/3.532, allocations: 64 MB / 1.292 GB, free: 10.7 MB / 0.8551 GB Notification: Performance of prepare preOptimizeDAE: time 4.38e-05/3.532, allocations: 11.98 kB / 1.293 GB, free: 10.69 MB / 0.8551 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.04308/3.575, allocations: 10.33 MB / 1.303 GB, free: 392 kB / 0.8551 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.04201/3.617, allocations: 17.41 MB / 1.32 GB, free: 0.5117 MB / 0.8708 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.02059/3.638, allocations: 24.78 MB / 1.344 GB, free: 3.227 MB / 0.902 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.2929/3.931, allocations: 4.714 MB / 1.348 GB, free: 228.5 MB / 0.902 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.1244/4.055, allocations: 53.37 MB / 1.401 GB, free: 215 MB / 0.902 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.00237/4.057, allocations: 188.1 kB / 1.401 GB, free: 215 MB / 0.902 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.02095/4.078, allocations: 1.963 MB / 1.403 GB, free: 215 MB / 0.902 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001492/4.08, allocations: 1.707 MB / 1.404 GB, free: 215 MB / 0.902 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.08501/4.165, allocations: 25.71 MB / 1.429 GB, free: 213.8 MB / 0.902 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.347/4.512, allocations: 222 MB / 1.646 GB, free: 37.09 MB / 0.902 GB Notification: Performance of preOpt comSubExp (simulation): time 0.3629/4.875, allocations: 38.83 MB / 1.684 GB, free: 193.7 MB / 0.902 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.0377/4.913, allocations: 11.52 MB / 1.695 GB, free: 193.3 MB / 0.902 GB Notification: Performance of preOpt evalFunc (simulation): time 0.7916/5.704, allocations: 311 MB / 1.999 GB, free: 204.4 MB / 0.902 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.05719/5.761, allocations: 25.52 MB / 2.024 GB, free: 201.9 MB / 0.902 GB Notification: Performance of pre-optimization done (n=7660): time 7.114e-05/5.761, allocations: 0 / 2.024 GB, free: 201.9 MB / 0.902 GB Notification: Performance of matching and sorting (n=7668): time 0.4235/6.185, allocations: 114.1 MB / 2.135 GB, free: 171.1 MB / 0.902 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0004355/6.185, allocations: 1.537 MB / 2.137 GB, free: 169.3 MB / 0.902 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.0201/6.205, allocations: 17.03 MB / 2.154 GB, free: 157.4 MB / 0.902 GB Notification: Performance of collectPreVariables (initialization): time 0.01256/6.218, allocations: 0.7809 MB / 2.154 GB, free: 157.2 MB / 0.902 GB Notification: Performance of collectInitialEqns (initialization): time 0.009949/6.228, allocations: 15.31 MB / 2.169 GB, free: 146.1 MB / 0.902 GB Notification: Performance of collectInitialBindings (initialization): time 0.03093/6.259, allocations: 27.53 MB / 2.196 GB, free: 123.6 MB / 0.902 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.05258/6.311, allocations: 12.45 MB / 2.208 GB, free: 116.1 MB / 0.902 GB Notification: Performance of setup shared object (initialization): time 3.719e-05/6.311, allocations: 304.7 kB / 2.209 GB, free: 115.8 MB / 0.902 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.03709/6.349, allocations: 10.86 MB / 2.219 GB, free: 105.6 MB / 0.902 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.04374/6.392, allocations: 28.2 MB / 2.247 GB, free: 72.55 MB / 0.902 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.4638/6.856, allocations: 80.22 MB / 2.325 GB, free: 150 MB / 0.902 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0007752/6.857, allocations: 145.1 kB / 2.325 GB, free: 150 MB / 0.902 GB Notification: Performance of matching and sorting (n=10442) (initialization): time 0.1806/7.037, allocations: 54.38 MB / 2.378 GB, free: 147.3 MB / 0.902 GB Notification: Performance of prepare postOptimizeDAE: time 0.0003636/7.038, allocations: 276.2 kB / 2.379 GB, free: 147.3 MB / 0.902 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.001015/7.039, allocations: 0.5457 MB / 2.379 GB, free: 147.3 MB / 0.902 GB Notification: Performance of postOpt tearingSystem (initialization): time 1.618/8.657, allocations: 0.6416 GB / 3.021 GB, free: 244 MB / 1.011 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.02249/8.68, allocations: 8.023 MB / 3.029 GB, free: 244 MB / 1.011 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.1839/8.864, allocations: 57.49 MB / 3.085 GB, free: 230.1 MB / 1.011 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.03985/8.904, allocations: 3.075 MB / 3.088 GB, free: 230.1 MB / 1.011 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01557/8.919, allocations: 2.395 MB / 3.09 GB, free: 230.1 MB / 1.011 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.EconomiseurHP4.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP2.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP3.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurMP3.TwoPhaseFlowPipe.Q[1] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 2306 * Number of states: 0 () * Number of discrete variables: 400 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,VolumeAlimMPHP.Cs1.diff_on_2,EconomiseurMP.Cws1.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_2,Vanne_alimentationMPHP1.C2.diff_on_1,CapteurDebitEauCondenseur.C1.diff_on_2,perteChargeK.C2.diff_on_2,vanne_extraction.C2.diff_on_1,perteChargeK2.C2.diff_on_1,BallonHP.Ce2.diff_on_1,BallonHP.Ce3.diff_on_1,BallonHP.Cs.diff_on_2,BallonHP.Ce2.diff_on_2,BallonHP.Ce3.diff_on_2,BallonHP.Cm.diff_on_2,BallonHP.Cs.diff_on_1,VolumeEvapHP.Ce1.diff_on_1,BallonHP.Cd.diff_on_1,VolumeEvapHP.Ce2.diff_on_1,VolumeEvapHP.Ce3.diff_on_1,GainChargeHP.C1.diff_on_2,VolumeEvapHP.Ce1.diff_on_2,VolumeEvapHP.Ce2.diff_on_2,VolumeEvapHP.Ce3.diff_on_2,VolumeEvapHP.Cs.diff_on_1,EvaporateurHP.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurHP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurHP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurHP.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP4.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP4.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP4.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP1.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP3.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP3.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP2.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP2.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP1.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP2.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP3.TwoPhaseFlowPipe.C1.diff_on_2,BallonMP.Ce2.diff_on_1,BallonMP.Ce3.diff_on_1,BallonMP.Cs.diff_on_2,BallonMP.Ce2.diff_on_2,BallonMP.Ce3.diff_on_2,BallonMP.Cm.diff_on_2,BallonMP.Cs.diff_on_1,EvaporateurMP.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurMP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurMP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurMP.TwoPhaseFlowPipe.C1.diff_on_2,VolumeEvapMP.Ce1.diff_on_1,BallonMP.Cd.diff_on_1,VolumeEvapMP.Ce2.diff_on_1,VolumeEvapMP.Ce3.diff_on_1,GainChargeMP.C1.diff_on_2,VolumeEvapMP.Ce1.diff_on_2,VolumeEvapMP.Ce2.diff_on_2,VolumeEvapMP.Ce3.diff_on_2,VolumeEvapMP.Cs.diff_on_1,EconomiseurMP.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurMP.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP1.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurMP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP1.TwoPhaseFlowPipe.C2.diff_on_1,MelangeurHPMP.Cs1.diff_on_2,MelangeurHPMP.Ce1.diff_on_2,MelangeurHPMP.Ce2.diff_on_2,MelangeurHPMP.Cs1.diff_on_1,SurchauffeurMP2.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurMP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurMP3.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP3.TwoPhaseFlowPipe.C1.diff_on_2,BallonBP.Ce2.diff_on_1,BallonBP.Ce3.diff_on_1,BallonBP.Ce2.diff_on_2,BallonBP.Ce3.diff_on_2,BallonBP.Cm.diff_on_2,VolumeEvapBP.Ce1.diff_on_1,BallonBP.Cd.diff_on_1,VolumeEvapBP.Ce2.diff_on_1,VolumeEvapBP.Ce3.diff_on_1,BallonBP.Cd.diff_on_2,VolumeEvapBP.Ce1.diff_on_2,VolumeEvapBP.Ce2.diff_on_2,VolumeEvapBP.Ce3.diff_on_2,VolumeEvapBP.Cs.diff_on_1,EvaporateurBP.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurBP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurBP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurBP.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurBP.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurBP.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurBP.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurBP.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurBP.ExchangerFlueGasesMetal.C1.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_1,MelangeurPreTMP.Cs.diff_on_2,MelangeurPostTMP1.Ce1.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_2,DoubleDebitHP.Ce.diff_on_2,DoubleDebitMP.Ce.diff_on_2,VolumePreTHP.Cs3.diff_on_2,MoitieDebitHP.Ce.diff_on_2,MoitieDebitHP.Cs.diff_on_1,VolumeCond1.Ce1.diff_on_1,VolumeCond1.Ce2.diff_on_1,VolumeCond1.Ce1.diff_on_2,VolumeCond1.Ce2.diff_on_2,VolumeCond1.Ce3.diff_on_2,EconomiseurBP.Cws1.diff_on_1,VolumeCond1.Cs.diff_on_1,VolumeCond1.Cs.diff_on_2,EconomiseurBP.TwoPhaseFlowPipe.C1.diff_on_2,VolumeAlimMPHP.Ce2.diff_on_1,VolumeAlimMPHP.Ce2.diff_on_2,MoitieDebitBP.Cs.diff_on_1,DoubleDebitBP.Ce.diff_on_2,MelangeurPostTMP1.Ce2.diff_on_1,DoubleDebitBP.Cs.diff_on_1,DoubleDebitBP.Cs.diff_on_2,MelangeurPostTMP1.Ce2.diff_on_2,CapteurDebitVapHP.C2.diff_on_1,BallonHP.Cv.diff_on_1,vanne_vapeurHP.C1.diff_on_2,SurchauffeurHP1.TwoPhaseFlowPipe.C1.diff_on_2,BallonHP.Ce1.diff_on_1,EconomiseurHP4.TwoPhaseFlowPipe.C2.diff_on_1,CapteurDebitEauHP.C1.diff_on_2,BallonHP.Ce1.diff_on_2,BallonMP.Ce1.diff_on_1,EconomiseurMP.TwoPhaseFlowPipe.C2.diff_on_1,CapteurDebitEauMP.C1.diff_on_2,BallonMP.Ce1.diff_on_2,CapteurDebitVapMP.C2.diff_on_1,BallonMP.Cv.diff_on_1,vanne_vapeurMP.C1.diff_on_2,SurchauffeurMP1.TwoPhaseFlowPipe.C1.diff_on_2,CapteurDebitVapBP.C2.diff_on_1,BallonBP.Cv.diff_on_1,vanne_vapeurBP.C1.diff_on_2,SurchauffeurBP.TwoPhaseFlowPipe.C1.diff_on_2,BallonBP.Ce1.diff_on_1,EconomiseurBP.TwoPhaseFlowPipe.C2.diff_on_1,CapteurDebitEauBP.C1.diff_on_2,BallonBP.Ce1.diff_on_2,Vanne_alimentationMPHP.C2.diff_on_1,BallonBP.Cs.diff_on_1,CapteurDebitEauBPsortie.C1.diff_on_2,VolumeAlimMPHP.Ce1.diff_on_2,PompeAlimBP.C2.diff_on_1,perteChargeK.C2.diff_on_1,Condenseur.Cl.diff_on_1,PompeAlimBP.C2.diff_on_2,vanne_extraction.C2.diff_on_2,MoitieDebitBP.Ce.diff_on_2,CapteurDebitVapCondenseur.C2.diff_on_1,TurbineBP.Cs.diff_on_1,MelangeurPostTMP1.Cs.diff_on_1,MelangeurPostTMP1.Cs.diff_on_2,TurbineBP.Cs.diff_on_2,Condenseur.Cv.diff_on_2,SurchauffeurMP2.Cws1.diff_on_1,MelangeurHPMP.Cs2.diff_on_1,lumpedStraightPipeK2.C1.diff_on_2,SurchauffeurMP2.TwoPhaseFlowPipe.C1.diff_on_2,vanne_entree_TurbineHP.C2.diff_on_1,DoubleDebitHP.Cs.diff_on_1,VolumeECO_HP1_2.Ce2.diff_on_1,VolumeECO_HP1_2.Ce3.diff_on_1,VolumeECO_HP1_2.Ce1.diff_on_2,VolumeECO_HP1_2.Ce2.diff_on_2,VolumeECO_HP1_2.Ce3.diff_on_2,VolumeECO_HP1_2.Cs.diff_on_1,VolumeECO_HP2_3.Ce2.diff_on_1,VolumeECO_HP2_3.Ce3.diff_on_1,VolumeECO_HP2_3.Ce1.diff_on_2,VolumeECO_HP2_3.Ce2.diff_on_2,VolumeECO_HP2_3.Ce3.diff_on_2,VolumeECO_HP2_3.Cs.diff_on_1,Vanne_alimentationMPHP1.C1.diff_on_1,perteChargeK3.C2.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_1,perteChargeK3.C2.diff_on_2,Vanne_alimentationMPHP1.C1.diff_on_2,EconomiseurHP1.TwoPhaseFlowPipe.C1.diff_on_2,PompeAlimMP.C2.diff_on_1,perteChargeK8.C2.diff_on_1,VolumeAlimMPHP.Cs1.diff_on_1,perteChargeK8.C2.diff_on_2,PompeAlimMP.C2.diff_on_2,EconomiseurMP.TwoPhaseFlowPipe.C1.diff_on_2,VolumePreTHP.Cs1.diff_on_2,VolumePreTHP.Cs2.diff_on_2,DoubleDebitHP.Cs.diff_on_2,VolumePreTHP.Ce.diff_on_2,VolumePreTHP.Cs1.diff_on_1,VolumePreTHP.Cs2.diff_on_1,TurbineHP.Cs.diff_on_1,VolumePreTHP.Cs3.diff_on_1,MelangeurPreTMP.Ce2.diff_on_1,MelangeurPreTMP.Ce3.diff_on_1,MelangeurPreTMP.Ce2.diff_on_2,MelangeurPreTMP.Ce3.diff_on_2,TurbineMP.Cs.diff_on_1,MelangeurPreTMP.Cs.diff_on_1,vanne_entree_TurbineMP.C2.diff_on_1,DoubleDebitMP.Cs.diff_on_1,DoubleDebitMP.Cs.diff_on_2,MelangeurPreTMP.Ce1.diff_on_2,VolumeEvapHP.fluid1,VolumeEvapMP.fluid1,MelangeurHPMP.fluid1,VolumeEvapBP.fluid1,MelangeurPostTMP1.fluid1,DoubleDebitHP.fluid1,DoubleDebitMP.fluid1,MoitieDebitHP.fluid1,SourceCaloporteur.fluid1,VolumeCond1.fluid1,VolumeAlimMPHP.fluid1,MoitieDebitBP.fluid1,DoubleDebitBP.fluid1,VolumeECO_HP1_2.fluid1,VolumeECO_HP2_3.fluid1,VolumePreTHP.fluid1,MelangeurPreTMP.fluid1,SourceFumees.fluid1,BallonHP.fluids[1],BallonHP.Ce2.ftype,BallonHP.Ce3.ftype,BallonHP.Cs.ftype,VolumeEvapHP.fluids[1],BallonHP.Cd.ftype,VolumeEvapHP.Ce2.ftype,VolumeEvapHP.Ce3.ftype,VolumeEvapHP.Cs.ftype,BallonMP.fluids[1],BallonMP.Ce2.ftype,BallonMP.Ce3.ftype,BallonMP.Cs.ftype,VolumeEvapMP.fluids[1],BallonMP.Cd.ftype,VolumeEvapMP.Ce2.ftype,VolumeEvapMP.Ce3.ftype,VolumeEvapMP.Cs.ftype,MelangeurHPMP.fluids[1],MelangeurHPMP.Cs1.ftype,BallonBP.fluids[1],BallonBP.Ce2.ftype,BallonBP.Ce3.ftype,VolumeEvapBP.fluids[1],BallonBP.Cd.ftype,VolumeEvapBP.Ce2.ftype,VolumeEvapBP.Ce3.ftype,VolumeEvapBP.Cs.ftype,MelangeurPostTMP1.fluids[1],MelangeurPostTMP1.Ce3.ftype,DoubleDebitHP.fluids[1],DoubleDebitMP.fluids[1],MoitieDebitHP.fluids[1],MoitieDebitHP.Cs.ftype,SourceCaloporteur.C.ftype,VolumeCond1.fluids[1],VolumeCond1.Ce1.ftype,VolumeCond1.Ce2.ftype,VolumeAlimMPHP.fluids[1],VolumeAlimMPHP.Ce2.ftype,MoitieDebitBP.fluids[1],MoitieDebitBP.Cs.ftype,DoubleDebitBP.fluids[1],DoubleDebitBP.Cs.ftype,BallonHP.Cv.ftype,BallonMP.Cv.ftype,BallonBP.Cv.ftype,VolumeCond1.Cs.ftype,BallonBP.Cs.ftype,Condenseur.Cl.ftype,MelangeurPostTMP1.Cs.ftype,MelangeurHPMP.Cs2.ftype,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,VolumeECO_HP1_2.fluids[1],VolumeECO_HP1_2.Ce2.ftype,VolumeECO_HP1_2.Ce3.ftype,VolumeECO_HP2_3.fluids[1],VolumeECO_HP1_2.Cs.ftype,VolumeECO_HP2_3.Ce2.ftype,VolumeECO_HP2_3.Ce3.ftype,VolumeECO_HP2_3.Cs.ftype,VolumeAlimMPHP.Cs2.ftype,VolumeAlimMPHP.Cs1.ftype,VolumePreTHP.fluids[1],DoubleDebitHP.Cs.ftype,VolumePreTHP.Cs1.ftype,VolumePreTHP.Cs2.ftype,VolumePreTHP.Cs3.ftype,MelangeurPreTMP.fluids[1],MelangeurPreTMP.Ce2.ftype,MelangeurPreTMP.Ce3.ftype,MelangeurPreTMP.Cs.ftype,DoubleDebitMP.Cs.ftype,SourceFumees.C.ftype,PuitsFumees.fluid,PuitsCaloporteur.fluid,vanne_entree_TurbineMP.fluid,Vanne_alimentationMPHP2.fluid,Vanne_alimentationMPHP1.fluid,vanne_entree_TurbineHP.fluid,lumpedStraightPipeK2.fluid,vanne_extraction.fluid,perteChargeK2.fluid,PompeAlimBP.fluid,perteChargeK.fluid,perteChargeK8.fluid,perteChargeK3.fluid,PerteChargeZero2.fluid,PompeAlimHP.fluid,PompeAlimMP.fluid,perteChargeKCond1.fluid,perteChargeK1.fluid,Condenseur.fluid_p,TurbineBP.fluid,TurbineMP.fluid,TurbineHP.fluid,EconomiseurBP.TwoPhaseFlowPipe.fluid,EconomiseurBP.ExchangerFlueGasesMetal.fluid,SurchauffeurBP.TwoPhaseFlowPipe.fluid,SurchauffeurBP.ExchangerFlueGasesMetal.fluid,Vanne_alimentationMPHP.fluid,EvaporateurBP.TwoPhaseFlowPipe.fluid,EvaporateurBP.ExchangerFlueGasesMetal.fluid,GainChargeBP.fluid,vanne_alimentationBP.fluid,vanne_vapeurBP.fluid,SurchauffeurMP3.TwoPhaseFlowPipe.fluid,SurchauffeurMP3.ExchangerFlueGasesMetal.fluid,SurchauffeurMP2.TwoPhaseFlowPipe.fluid,SurchauffeurMP2.ExchangerFlueGasesMetal.fluid,SurchauffeurMP1.TwoPhaseFlowPipe.fluid,SurchauffeurMP1.ExchangerFlueGasesMetal.fluid,EconomiseurMP.TwoPhaseFlowPipe.fluid,EconomiseurMP.ExchangerFlueGasesMetal.fluid,GainChargeMP.fluid,EvaporateurMP.TwoPhaseFlowPipe.fluid,EvaporateurMP.ExchangerFlueGasesMetal.fluid,vanne_vapeurMP.fluid,vanne_alimentationMP.fluid,SurchauffeurHP3.TwoPhaseFlowPipe.fluid,SurchauffeurHP3.ExchangerFlueGasesMetal.fluid,SurchauffeurHP2.TwoPhaseFlowPipe.fluid,SurchauffeurHP2.ExchangerFlueGasesMetal.fluid,EconomiseurHP1.TwoPhaseFlowPipe.fluid,EconomiseurHP1.ExchangerFlueGasesMetal.fluid,EconomiseurHP2.TwoPhaseFlowPipe.fluid,EconomiseurHP2.ExchangerFlueGasesMetal.fluid,EconomiseurHP3.TwoPhaseFlowPipe.fluid,EconomiseurHP3.ExchangerFlueGasesMetal.fluid,SurchauffeurHP1.TwoPhaseFlowPipe.fluid,SurchauffeurHP1.ExchangerFlueGasesMetal.fluid,EconomiseurHP4.TwoPhaseFlowPipe.fluid,EconomiseurHP4.ExchangerFlueGasesMetal.fluid,EvaporateurHP.TwoPhaseFlowPipe.fluid,EvaporateurHP.ExchangerFlueGasesMetal.fluid,GainChargeHP.fluid,vanne_vapeurHP.fluid,vanne_alimentationHP.fluid,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,$whenCondition1) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (4043): * Single equations (assignments): 3990 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 34 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 12 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 5 systems {1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(4,1,62.5%)} * Non-linear torn systems (#iteration vars, #inner vars): 11 systems {(1,1), (1,5), (2,11), (1,15), (1,1), (1,15), (305,2988), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.04031/8.959, allocations: 3.664 MB / 3.094 GB, free: 229.8 MB / 1.011 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.03327/8.993, allocations: 3.725 MB / 3.097 GB, free: 228.2 MB / 1.011 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.1847/9.177, allocations: 61.18 MB / 3.157 GB, free: 187.7 MB / 1.011 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.1391/9.316, allocations: 43.94 MB / 3.2 GB, free: 152.3 MB / 1.011 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0002115/9.317, allocations: 24 kB / 3.2 GB, free: 152.2 MB / 1.011 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001598/9.318, allocations: 305.4 kB / 3.2 GB, free: 152.2 MB / 1.011 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.6518/9.97, allocations: 108.4 MB / 3.306 GB, free: 223.9 MB / 1.011 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0007592/9.971, allocations: 78.17 kB / 3.306 GB, free: 223.9 MB / 1.011 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.03299/10, allocations: 9.485 MB / 3.315 GB, free: 223.9 MB / 1.011 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.09043/10.09, allocations: 37.09 MB / 3.352 GB, free: 220.8 MB / 1.011 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0194/10.11, allocations: 1.738 MB / 3.353 GB, free: 220.8 MB / 1.011 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.1127/10.23, allocations: 173 MB / 3.522 GB, free: 77.29 MB / 1.011 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.479e-05/10.23, allocations: 38.66 kB / 3.522 GB, free: 77.28 MB / 1.011 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.2228/10.45, allocations: 74.98 MB / 3.595 GB, free: 60.88 MB / 1.011 GB Notification: Performance of postOpt removeConstants (simulation): time 0.0377/10.49, allocations: 9.389 MB / 3.605 GB, free: 58.11 MB / 1.011 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.02203/10.51, allocations: 1.231 MB / 3.606 GB, free: 58.05 MB / 1.011 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.04066/10.55, allocations: 2.469 MB / 3.608 GB, free: 57.56 MB / 1.011 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.02299/10.57, allocations: 4.502 MB / 3.613 GB, free: 54.99 MB / 1.011 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.01763/10.59, allocations: 1.547 MB / 3.614 GB, free: 54.47 MB / 1.011 GB Notification: Performance of sorting global known variables: time 0.01209/10.6, allocations: 7.72 MB / 3.622 GB, free: 52.42 MB / 1.011 GB Notification: Performance of sort global known variables: time 1.81e-07/10.6, allocations: 0 / 3.622 GB, free: 52.42 MB / 1.011 GB Notification: Performance of remove unused functions: time 0.07986/10.68, allocations: 18.73 MB / 3.64 GB, free: 36.64 MB / 1.011 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 105 * Number of states: 249 (BallonHP.P,BallonHP.hl,BallonHP.hv,BallonHP.Tp,BallonHP.Vv,VolumeEvapHP.h,EvaporateurHP.ExchangerWall.Tp[1],EvaporateurHP.ExchangerWall.Tp[2],EvaporateurHP.ExchangerWall.Tp[3],EvaporateurHP.TwoPhaseFlowPipe.P[2],EvaporateurHP.TwoPhaseFlowPipe.P[3],EvaporateurHP.TwoPhaseFlowPipe.P[4],EvaporateurHP.TwoPhaseFlowPipe.Q[1],EvaporateurHP.TwoPhaseFlowPipe.Q[2],EvaporateurHP.TwoPhaseFlowPipe.Q[3],EvaporateurHP.TwoPhaseFlowPipe.Q[4],EvaporateurHP.TwoPhaseFlowPipe.h[2],EvaporateurHP.TwoPhaseFlowPipe.h[3],EvaporateurHP.TwoPhaseFlowPipe.h[4],EconomiseurHP4.ExchangerWall.Tp[1],EconomiseurHP4.ExchangerWall.Tp[2],EconomiseurHP4.ExchangerWall.Tp[3],EconomiseurHP4.TwoPhaseFlowPipe.P[2],EconomiseurHP4.TwoPhaseFlowPipe.P[3],EconomiseurHP4.TwoPhaseFlowPipe.P[4],EconomiseurHP4.TwoPhaseFlowPipe.Q[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[3],EconomiseurHP4.TwoPhaseFlowPipe.Q[4],EconomiseurHP4.TwoPhaseFlowPipe.h[2],EconomiseurHP4.TwoPhaseFlowPipe.h[3],EconomiseurHP4.TwoPhaseFlowPipe.h[4],SurchauffeurHP1.ExchangerWall.Tp[1],SurchauffeurHP1.ExchangerWall.Tp[2],SurchauffeurHP1.ExchangerWall.Tp[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[2],SurchauffeurHP1.TwoPhaseFlowPipe.P[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[4],SurchauffeurHP1.TwoPhaseFlowPipe.Q[1],SurchauffeurHP1.TwoPhaseFlowPipe.Q[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[2],SurchauffeurHP1.TwoPhaseFlowPipe.h[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[4],EconomiseurHP3.ExchangerWall.Tp[1],EconomiseurHP3.ExchangerWall.Tp[2],EconomiseurHP3.ExchangerWall.Tp[3],EconomiseurHP3.TwoPhaseFlowPipe.P[2],EconomiseurHP3.TwoPhaseFlowPipe.P[3],EconomiseurHP3.TwoPhaseFlowPipe.P[4],EconomiseurHP3.TwoPhaseFlowPipe.Q[1],EconomiseurHP3.TwoPhaseFlowPipe.Q[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[3],EconomiseurHP3.TwoPhaseFlowPipe.Q[4],EconomiseurHP3.TwoPhaseFlowPipe.h[2],EconomiseurHP3.TwoPhaseFlowPipe.h[3],EconomiseurHP3.TwoPhaseFlowPipe.h[4],EconomiseurHP2.ExchangerWall.Tp[1],EconomiseurHP2.ExchangerWall.Tp[2],EconomiseurHP2.ExchangerWall.Tp[3],EconomiseurHP2.TwoPhaseFlowPipe.P[2],EconomiseurHP2.TwoPhaseFlowPipe.P[3],EconomiseurHP2.TwoPhaseFlowPipe.P[4],EconomiseurHP2.TwoPhaseFlowPipe.Q[1],EconomiseurHP2.TwoPhaseFlowPipe.Q[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[3],EconomiseurHP2.TwoPhaseFlowPipe.Q[4],EconomiseurHP2.TwoPhaseFlowPipe.h[2],EconomiseurHP2.TwoPhaseFlowPipe.h[3],EconomiseurHP2.TwoPhaseFlowPipe.h[4],EconomiseurHP1.ExchangerWall.Tp[1],EconomiseurHP1.ExchangerWall.Tp[2],EconomiseurHP1.ExchangerWall.Tp[3],EconomiseurHP1.TwoPhaseFlowPipe.P[2],EconomiseurHP1.TwoPhaseFlowPipe.P[3],EconomiseurHP1.TwoPhaseFlowPipe.P[4],EconomiseurHP1.TwoPhaseFlowPipe.Q[1],EconomiseurHP1.TwoPhaseFlowPipe.Q[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[3],EconomiseurHP1.TwoPhaseFlowPipe.Q[4],EconomiseurHP1.TwoPhaseFlowPipe.h[2],EconomiseurHP1.TwoPhaseFlowPipe.h[3],EconomiseurHP1.TwoPhaseFlowPipe.h[4],SurchauffeurHP2.ExchangerWall.Tp[1],SurchauffeurHP2.ExchangerWall.Tp[2],SurchauffeurHP2.ExchangerWall.Tp[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[2],SurchauffeurHP2.TwoPhaseFlowPipe.P[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[4],SurchauffeurHP2.TwoPhaseFlowPipe.Q[1],SurchauffeurHP2.TwoPhaseFlowPipe.Q[2],SurchauffeurHP2.TwoPhaseFlowPipe.Q[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[2],SurchauffeurHP2.TwoPhaseFlowPipe.h[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[4],SurchauffeurHP3.ExchangerWall.Tp[1],SurchauffeurHP3.ExchangerWall.Tp[2],SurchauffeurHP3.ExchangerWall.Tp[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[2],SurchauffeurHP3.TwoPhaseFlowPipe.P[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[4],SurchauffeurHP3.TwoPhaseFlowPipe.Q[1],SurchauffeurHP3.TwoPhaseFlowPipe.Q[2],SurchauffeurHP3.TwoPhaseFlowPipe.Q[3],SurchauffeurHP3.TwoPhaseFlowPipe.Q[4],SurchauffeurHP3.TwoPhaseFlowPipe.h[2],SurchauffeurHP3.TwoPhaseFlowPipe.h[3],SurchauffeurHP3.TwoPhaseFlowPipe.h[4],BallonMP.P,BallonMP.hl,BallonMP.hv,BallonMP.Tp,BallonMP.Vv,EvaporateurMP.ExchangerWall.Tp[1],EvaporateurMP.ExchangerWall.Tp[2],EvaporateurMP.ExchangerWall.Tp[3],EvaporateurMP.TwoPhaseFlowPipe.P[2],EvaporateurMP.TwoPhaseFlowPipe.P[3],EvaporateurMP.TwoPhaseFlowPipe.P[4],EvaporateurMP.TwoPhaseFlowPipe.Q[1],EvaporateurMP.TwoPhaseFlowPipe.Q[2],EvaporateurMP.TwoPhaseFlowPipe.Q[3],EvaporateurMP.TwoPhaseFlowPipe.Q[4],EvaporateurMP.TwoPhaseFlowPipe.h[2],EvaporateurMP.TwoPhaseFlowPipe.h[3],EvaporateurMP.TwoPhaseFlowPipe.h[4],VolumeEvapMP.h,EconomiseurMP.ExchangerWall.Tp[1],EconomiseurMP.ExchangerWall.Tp[2],EconomiseurMP.ExchangerWall.Tp[3],EconomiseurMP.TwoPhaseFlowPipe.P[2],EconomiseurMP.TwoPhaseFlowPipe.P[3],EconomiseurMP.TwoPhaseFlowPipe.P[4],EconomiseurMP.TwoPhaseFlowPipe.Q[1],EconomiseurMP.TwoPhaseFlowPipe.Q[2],EconomiseurMP.TwoPhaseFlowPipe.Q[3],EconomiseurMP.TwoPhaseFlowPipe.Q[4],EconomiseurMP.TwoPhaseFlowPipe.h[2],EconomiseurMP.TwoPhaseFlowPipe.h[3],EconomiseurMP.TwoPhaseFlowPipe.h[4],SurchauffeurMP1.ExchangerWall.Tp[1],SurchauffeurMP1.ExchangerWall.Tp[2],SurchauffeurMP1.ExchangerWall.Tp[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[2],SurchauffeurMP1.TwoPhaseFlowPipe.P[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[4],SurchauffeurMP1.TwoPhaseFlowPipe.Q[1],SurchauffeurMP1.TwoPhaseFlowPipe.Q[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[3],SurchauffeurMP1.TwoPhaseFlowPipe.Q[4],SurchauffeurMP1.TwoPhaseFlowPipe.h[2],SurchauffeurMP1.TwoPhaseFlowPipe.h[3],SurchauffeurMP1.TwoPhaseFlowPipe.h[4],MelangeurHPMP.h,SurchauffeurMP2.ExchangerWall.Tp[1],SurchauffeurMP2.ExchangerWall.Tp[2],SurchauffeurMP2.ExchangerWall.Tp[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[2],SurchauffeurMP2.TwoPhaseFlowPipe.P[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[4],SurchauffeurMP2.TwoPhaseFlowPipe.Q[1],SurchauffeurMP2.TwoPhaseFlowPipe.Q[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[2],SurchauffeurMP2.TwoPhaseFlowPipe.h[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[4],SurchauffeurMP3.ExchangerWall.Tp[1],SurchauffeurMP3.ExchangerWall.Tp[2],SurchauffeurMP3.ExchangerWall.Tp[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[2],SurchauffeurMP3.TwoPhaseFlowPipe.P[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[4],SurchauffeurMP3.TwoPhaseFlowPipe.Q[1],SurchauffeurMP3.TwoPhaseFlowPipe.Q[2],SurchauffeurMP3.TwoPhaseFlowPipe.Q[3],SurchauffeurMP3.TwoPhaseFlowPipe.Q[4],SurchauffeurMP3.TwoPhaseFlowPipe.h[2],SurchauffeurMP3.TwoPhaseFlowPipe.h[3],SurchauffeurMP3.TwoPhaseFlowPipe.h[4],BallonBP.P,BallonBP.hl,BallonBP.hv,BallonBP.Tp,BallonBP.Vv,VolumeEvapBP.h,EvaporateurBP.ExchangerWall.Tp[1],EvaporateurBP.ExchangerWall.Tp[2],EvaporateurBP.ExchangerWall.Tp[3],EvaporateurBP.TwoPhaseFlowPipe.P[2],EvaporateurBP.TwoPhaseFlowPipe.P[3],EvaporateurBP.TwoPhaseFlowPipe.P[4],EvaporateurBP.TwoPhaseFlowPipe.Q[1],EvaporateurBP.TwoPhaseFlowPipe.Q[2],EvaporateurBP.TwoPhaseFlowPipe.Q[3],EvaporateurBP.TwoPhaseFlowPipe.Q[4],EvaporateurBP.TwoPhaseFlowPipe.h[2],EvaporateurBP.TwoPhaseFlowPipe.h[3],EvaporateurBP.TwoPhaseFlowPipe.h[4],SurchauffeurBP.ExchangerWall.Tp[1],SurchauffeurBP.ExchangerWall.Tp[2],SurchauffeurBP.ExchangerWall.Tp[3],SurchauffeurBP.TwoPhaseFlowPipe.P[2],SurchauffeurBP.TwoPhaseFlowPipe.P[3],SurchauffeurBP.TwoPhaseFlowPipe.P[4],SurchauffeurBP.TwoPhaseFlowPipe.Q[1],SurchauffeurBP.TwoPhaseFlowPipe.Q[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[3],SurchauffeurBP.TwoPhaseFlowPipe.Q[4],SurchauffeurBP.TwoPhaseFlowPipe.h[2],SurchauffeurBP.TwoPhaseFlowPipe.h[3],SurchauffeurBP.TwoPhaseFlowPipe.h[4],EconomiseurBP.ExchangerWall.Tp[1],EconomiseurBP.ExchangerWall.Tp[2],EconomiseurBP.ExchangerWall.Tp[3],EconomiseurBP.TwoPhaseFlowPipe.P[2],EconomiseurBP.TwoPhaseFlowPipe.P[3],EconomiseurBP.TwoPhaseFlowPipe.P[4],EconomiseurBP.TwoPhaseFlowPipe.Q[1],EconomiseurBP.TwoPhaseFlowPipe.Q[2],EconomiseurBP.TwoPhaseFlowPipe.Q[3],EconomiseurBP.TwoPhaseFlowPipe.Q[4],EconomiseurBP.TwoPhaseFlowPipe.h[2],EconomiseurBP.TwoPhaseFlowPipe.h[3],EconomiseurBP.TwoPhaseFlowPipe.h[4],MelangeurPostTMP1.h,Condenseur.P,Condenseur.hl,Condenseur.hv,Condenseur.Vv,VolumeCond1.h,VolumeAlimMPHP.h,regulation_Niveau_HP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_3.x,VolumeECO_HP1_2.P,VolumeECO_HP1_2.h,VolumeECO_HP2_3.P,VolumeECO_HP2_3.h,VolumePreTHP.P,VolumePreTHP.h,MelangeurPreTMP.P,MelangeurPreTMP.h) * Number of discrete variables: 17 ($whenCondition1,regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal,perteChargeK2.C2.diff_on_1,vanne_extraction.C2.diff_on_1,CapteurDebitEauCondenseur.C1.diff_on_2,perteChargeK.C2.diff_on_2,Vanne_alimentationMPHP1.C2.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_2,EconomiseurMP.Cws1.diff_on_1,VolumeAlimMPHP.Cs1.diff_on_2) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (5191): * Single equations (assignments): 4782 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 256 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 4 * Torn equation systems: 142 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 4 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 55 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,2,100.0%), (1,2,100.0%), (1,2,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 87 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,5), (1,3), (2,8), (1,5), (1,3), (2,8), (1,5), (1,5), (1,3), (1,3), (48,433), (1,4), (1,4), (1,4), (1,5), (1,3), (5,16), (1,5), (1,2), (1,2), (1,5), (4,18), (1,3), (3,9)} Notification: Performance of Backend phase and start with SimCode phase: time 0.0313/10.71, allocations: 6.424 MB / 3.646 GB, free: 31.61 MB / 1.011 GB Notification: Performance of simCode: created initialization part: time 0.4829/11.2, allocations: 87.15 MB / 3.731 GB, free: 187 MB / 1.011 GB Notification: Performance of simCode: created event and clocks part: time 0.001488/11.2, allocations: 475.5 kB / 3.732 GB, free: 186.9 MB / 1.011 GB Notification: Performance of simCode: created simulation system equations: time 0.08529/11.28, allocations: 42.8 MB / 3.774 GB, free: 170.4 MB / 1.011 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.08913/11.37, allocations: 17.28 MB / 3.79 GB, free: 168.5 MB / 1.011 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.2427/11.61, allocations: 114.9 MB / 3.903 GB, free: 132.2 MB / 1.011 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.0313/11.65, allocations: 12.97 MB / 3.915 GB, free: 130.6 MB / 1.011 GB Notification: Performance of simCode: alias equations: time 0.04582/11.69, allocations: 7.003 MB / 3.922 GB, free: 125.5 MB / 1.011 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.07202/11.76, allocations: 12.44 MB / 3.934 GB, free: 115 MB / 1.011 GB Notification: Performance of SimCode: time 2.164e-06/11.76, allocations: 0 / 3.934 GB, free: 115 MB / 1.011 GB Notification: Performance of Templates: time 3.258/15.02, allocations: 1.533 GB / 5.467 GB, free: 235.4 MB / 1.043 GB " [Timeout remaining time 645] make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.makefile [Timeout 660] (rm -f ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe >> ../files/ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.sim & ./ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC -abortSlowSimulation -alarm=240 -lv LOG_STATS > ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe 2>&1) [Timeout 240] [Calling os._exit(0), Time elapsed: 70.19749525515363]