Environment - simulationEnvironment: startTime=0 stopTime=0.2 tolerance=1e-06 numberOfIntervals=4000 stepSize=5e-05 Regular simulation: ./Modelica_4.1.0_Modelica.Electrical.Polyphase.Examples.PolyphaseRectifier -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0199213s reading init.xml | | | | | | 0.00181966s reading info.xml | | | | | | 0.000630435s [ 0.7%] pre-initialization | | | | | | 0.000801065s [ 0.9%] initialization | | | | | | 6.2918e-05s [ 0.1%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000855007s [ 0.9%] creating output-file | | | | | | 0.00246155s [ 2.7%] event-handling | | | | | | 0.000566831s [ 0.6%] overhead | | | | | | 0.0853249s [ 94.1%] simulation | | | | | | 0.0907027s [100.0%] total | | | | | events | | | | | | 240 state events | | | | | | 20 time events | | | | | solver: gbode | | | | | | 1312 steps taken | | | | | | 6389 calls of functionODE | | | | | | 252 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00413576s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.