Environment - simulationEnvironment: startTime=1.6848e+07 stopTime=1.728e+07 tolerance=1e-07 numberOfIntervals=10127 stepSize=42.6582 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Summer -abortSlowSimulation -alarm=420 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.10.08 11:37 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 07/15/2006 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848000.000000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -3.2842e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848000.000000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -2.92234e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848000.000000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -3.2842e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848000.000000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -2.92234e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16848000.000000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -4.33235e-13" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16848000.000001 | | | | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -2.14751e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16848000.000001 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -5.294e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Sensors/VolumeFlowRate.mo:19:3-26:24:writable] | | | | The following assertion has been violated at time 16848000.000001 | | | | ((hvac.VOut1.V_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VOut1.V_flow, has value: -9.7624e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16870540.259873 | | | | ((hvac.conVAV[2].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16870540.259873 | | | | ((hvac.conVAV[2].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16901931.180366 | | | | ((hvac.conVAV[1].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916423.817518 | | | | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -7.45036e-186" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:78:3-83:35:writable] | | | | The following assertion has been violated at time 16916466.475758 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -7.50925e-26" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16916466.475758 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -3.21705e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16916466.475758 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -4.6485e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916466.475758 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -1.19828e-98" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956111.263935 | | | | ((hvac.conVAV[4].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956128.042520 | | | | ((hvac.conVAV[3].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956300.000000 | | | | ((hvac.conVAV[1].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956300.000000 | | | | ((hvac.conVAV[4].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956300.000000 | | | | ((hvac.conVAV[5].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956300.000000 | | | | ((hvac.conVAV[5].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 17002869.166061 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -8.87879e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 17047389.734186 | | | | ((hvac.conVAV[3].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.244884s reading init.xml | | | | | | 0.0361129s reading info.xml | | | | | | 0.00413489s [ 0.0%] pre-initialization | | | | | | 5.56521s [ 28.0%] initialization | | | | | | 0.00104843s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.0113076s [ 0.1%] creating output-file | | | | | | 2.10258s [ 10.6%] event-handling | | | | | | 0.106271s [ 0.5%] overhead | | | | | | 12.053s [ 60.7%] simulation | | | | | | 19.8435s [100.0%] total | | | | | events | | | | | | 942 state events | | | | | | 4180 time events | | | | | solver: gbode | | | | | | 24337 steps taken | | | | | | 116978 calls of functionODE | | | | | | 6474 evaluations of jacobian | | | | | | 9 error test failures | | | | | | 1122 convergence test failures | | | | | | 4.85804s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 14.57sec EnergyPlus Completed Successfully.