Environment - simulationEnvironment: startTime=0 stopTime=3000 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.2 Regular simulation: ./Buildings_latest_Buildings.Fluid.CHPs.BaseClasses.Validation.EnergyConversion -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | gbode (single-rate integration): radauIIA3 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0156513s reading init.xml | | | | | | 0.00107046s reading info.xml | | | | | | 0.000478449s [ 8.9%] pre-initialization | | | | | | 0.00126889s [ 23.6%] initialization | | | | | | 1.1501e-05s [ 0.2%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.00120832s [ 22.5%] creating output-file | | | | | | 9.0048e-05s [ 1.7%] event-handling | | | | | | 0.000697202s [ 13.0%] overhead | | | | | | 0.00161659s [ 30.1%] simulation | | | | | | 0.005371s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 9 time events | | | | | solver: gbode | | | | | | 96 steps taken | | | | | | 376 calls of functionODE | | | | | | 17 evaluations of jacobian | | | | | | 6 error test failures | | | | | | 0 convergence test failures | | | | | | 3.334e-06s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.