startTime=0
stopTime=3600
tolerance=1e-06
numberOfIntervals=2500
stepSize=1.44
wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS")
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Using pre-compiled FMU /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Resources/src/ThermalZones/EnergyPlus_9_6_0/FMUs/Zones3.fmu
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable North_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.#10;"
LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
LOG_STATS | info | ### STATISTICS ###
| | | | | timer
| | | | | | 0s reading init.xml
| | | | | | 0s reading info.xml
| | | | | | 4.7369e-05s [ 0.1%] pre-initialization
| | | | | | 0.0443011s [ 81.8%] initialization
| | | | | | 0s [ 0.0%] steps
| | | | | | 0.000912362s [ 1.7%] solver (excl. callbacks)
| | | | | | 0.000351649s [ 0.6%] creating output-file
| | | | | | 0.00276267s [ 5.1%] event-handling
| | | | | | 0s [ 0.0%] overhead
| | | | | | 0.00576358s [ 10.6%] simulation
| | | | | | 0.0541387s [100.0%] total
| | | | | events
| | | | | | 59 state events
| | | | | | 0 time events
| | | | | solver: dassl
| | | | | | 980 steps taken
| | | | | | 980 calls of functionODE
| | | | | | 920 evaluations of jacobian
| | | | | | 0 error test failures
| | | | | | 0 convergence test failures
| | | | | | 0.000270275s time of jacobian evaluation