Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0002209/0.0002209, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0001753/0.0001753, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 0.04429/0.04429, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo): time 0.03666/0.03666, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: simulate(Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2,startTime=0,stopTime=10.5,tolerance=0.001,numberOfIntervals=5250,outputFormat="empty",variableFilter="",fileNamePrefix="Dynawo_Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2",simflags="-lv=LOG_STATS -s=rungekutta -abortSlowSimulation -alarm=240 -lv LOG_STATS") simulate(Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2,startTime=0,stopTime=10.5,tolerance=0.001,numberOfIntervals=5250,outputFormat="empty",variableFilter="",fileNamePrefix="Dynawo_Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2",simflags="-lv=LOG_STATS -s=rungekutta -abortSlowSimulation -alarm=240 -lv LOG_STATS") [Timeout 900] "Notification: Performance of FrontEnd - loaded program: time 5.21e-07/5.21e-07, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 1.032e-05/1.084e-05, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.instantiate(Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2): time 0.005493/0.005503, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.instExpressions: time 0.003109/0.008613, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFInst.updateImplicitVariability: time 0.0003617/0.008974, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeComponents: time 0.000586/0.00956, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. Notification: Performance of NFTyping.typeBindings: time 0.0007305/0.01029, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFTyping.typeClassSections: time 0.0008701/0.01116, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:18:3-19:42:writable] Error: Parameter aSetPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:20:3-21:39:writable] Error: Parameter DeltaOmegaDbPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:22:3-23:39:writable] Error: Parameter DeltaOmegaMaxPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:24:3-25:39:writable] Error: Parameter DeltaOmegaMinPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:26:3-27:42:writable] Error: Parameter DeltaT has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:28:3-29:36:writable] Error: Parameter Dm has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:30:3-31:53:writable] Error: Parameter fLim10Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:32:3-33:53:writable] Error: Parameter fLim1Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:34:3-35:53:writable] Error: Parameter fLim2Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:36:3-37:53:writable] Error: Parameter fLim3Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:38:3-39:53:writable] Error: Parameter fLim4Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:40:3-41:53:writable] Error: Parameter fLim5Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:42:3-43:53:writable] Error: Parameter fLim6Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:44:3-45:53:writable] Error: Parameter fLim7Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:46:3-47:53:writable] Error: Parameter fLim8Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:48:3-49:53:writable] Error: Parameter fLim9Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:50:3-51:42:writable] Error: Parameter KA has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:52:3-53:39:writable] Error: Parameter KDGov has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:54:3-55:39:writable] Error: Parameter KIGov has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:56:3-57:43:writable] Error: Parameter KILoad has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:58:3-59:49:writable] Error: Parameter KIMw has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:60:3-61:39:writable] Error: Parameter KPGov has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:62:3-63:43:writable] Error: Parameter KPLoad has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:64:3-65:36:writable] Error: Parameter KTurb has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:66:3-67:29:writable] Error: Parameter PBaseMw has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:68:3-69:29:writable] Error: Parameter PGenBaseMw has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:70:3-71:43:writable] Error: Parameter PLdRefPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:72:3-73:53:writable] Error: Parameter PLim10Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:74:3-75:53:writable] Error: Parameter PLim1Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:76:3-77:53:writable] Error: Parameter PLim2Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:78:3-79:53:writable] Error: Parameter PLim3Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:80:3-81:53:writable] Error: Parameter PLim4Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:82:3-83:53:writable] Error: Parameter PLim5Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:84:3-85:53:writable] Error: Parameter PLim6Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:86:3-87:53:writable] Error: Parameter PLim7Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:88:3-89:53:writable] Error: Parameter PLim8Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:90:3-91:53:writable] Error: Parameter PLim9Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:92:3-93:53:writable] Error: Parameter PRatePu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:94:3-95:36:writable] Error: Parameter RClosePu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:96:3-97:43:writable] Error: Parameter RDownPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:98:3-99:36:writable] Error: Parameter ROpenPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:100:3-101:39:writable] Error: Parameter RDroop has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:102:3-103:39:writable] Error: Parameter RSelectInt has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:104:3-105:43:writable] Error: Parameter RUpPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:106:3-107:36:writable] Error: Parameter tActuator has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:108:3-109:42:writable] Error: Parameter tA has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:110:3-111:36:writable] Error: Parameter tB has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:112:3-113:36:writable] Error: Parameter tC has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:114:3-115:39:writable] Error: Parameter tDGov has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:116:3-116:105:writable] Error: Parameter tDRatelim has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:117:3-118:36:writable] Error: Parameter tEngine has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:119:3-120:43:writable] Error: Parameter tFLoad has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:121:3-122:39:writable] Error: Parameter tLastValue has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:123:3-124:39:writable] Error: Parameter tPElec has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:125:3-126:43:writable] Error: Parameter tSA has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:127:3-128:43:writable] Error: Parameter tSB has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:129:3-130:36:writable] Error: Parameter ValveMaxPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:131:3-132:36:writable] Error: Parameter ValveMinPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:133:3-134:36:writable] Error: Parameter WFnlPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:135:3-136:36:writable] Error: Parameter WFSpdBool has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:287:3-287:203:writable] Error: Parameter PGen0Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:288:3-288:95:writable] Error: Parameter Pm0Pu has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of NFFlatten.flatten: time 0.0008113/0.01197, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFFlatten.resolveConnections: time 0.0003907/0.01236, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFEvalConstants.evaluate: time 0.0004775/0.01284, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFSimplifyModel.simplify: time 0.0004022/0.01324, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFPackage.collectConstants: time 9.774e-05/0.01334, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFFlatten.collectFunctions: time 0.0001415/0.01348, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFScalarize.scalarize: time 0.0002483/0.01373, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFVerifyModel.verify: time 0.0002611/0.01399, allocations: 0 / 0, free: 0 / 0 Notification: Performance of NFConvertDAE.convert: time 0.0008666/0.01486, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - DAE generated: time 0.0001033/0.01496, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd: time 1.142e-06/0.01496, allocations: 0 / 0, free: 0 / 0 Notification: Performance of Transformations before backend: time 5.22e-06/0.01497, allocations: 0 / 0, free: 0 / 0 Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 163 * Number of variables: 163 Notification: Performance of Generate backend data structure: time 0.001489/0.01646, allocations: 0 / 0, free: 0 / 0 Notification: Performance of prepare preOptimizeDAE: time 7.91e-05/0.01654, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt normalInlineFunction (simulation): time 0.000159/0.01669, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt evaluateParameters (simulation): time 0.0007549/0.01745, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt simplifyIfEquations (simulation): time 8.761e-05/0.01754, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt expandDerOperator (simulation): time 8.779e-05/0.01762, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt clockPartitioning (simulation): time 0.0006868/0.01831, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt findStateOrder (simulation): time 1.585e-05/0.01833, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt replaceEdgeChange (simulation): time 5.635e-05/0.01838, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt inlineArrayEqn (simulation): time 1.513e-05/0.0184, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt removeEqualRHS (simulation): time 0.0002914/0.01869, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.001962/0.02065, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt comSubExp (simulation): time 0.0005791/0.02123, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt resolveLoops (simulation): time 0.0001175/0.02135, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt evalFunc (simulation): time 3.132e-05/0.02138, allocations: 0 / 0, free: 0 / 0 Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 2.276e-05/0.0214, allocations: 0 / 0, free: 0 / 0 Notification: Performance of pre-optimization done (n=60): time 5.491e-06/0.02141, allocations: 0 / 0, free: 0 / 0 Notification: Performance of matching and sorting (n=60): time 0.000499/0.02191, allocations: 0 / 0, free: 0 / 0 Notification: Performance of inlineWhenForInitialization (initialization): time 2.455e-05/0.02193, allocations: 0 / 0, free: 0 / 0 Error: No system for the symbolic initialization was generated " [Timeout remaining time 900] [Calling sys.exit(0), Time elapsed: 0.5558230178430676]