startTime=0 stopTime=3000 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.2 wasm-jit simulation: simulate(ThermoPower.Examples.RankineCycle.Simulators.ClosedLoop,startTime=0,stopTime=3000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoPower_4.0.0-dev_ThermoPower.Examples.RankineCycle.Simulators.ClosedLoop",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") Simulation execution failed for model: ThermoPower.Examples.RankineCycle.Simulators.ClosedLoop LOG_STDOUT | warning | Sparsity pattern for non-linear system 1 is not regular. This indicates that something went wrong during sparsity pattern generation. Removing sparsity pattern and disabling NLS scaling. LOG_SUCCESS | info | The initialization finished successfully with 5 homotopy steps. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=45.6. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | Integrator attempt to handle a problem with a called assert. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7664289624903. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.9039069513484. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7664289624903. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7320594652757. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7406518395794. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7320594652757. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7299113716998. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7293743483059. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7292400924574. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7292065284952. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7291981375047. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7291960397571. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7291955153202. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7291953842109. | | | | For more information please use -lv LOG_NLS. DASKR-- AT T (=R1) AND STEPSIZE H (=R2) THE In above, R1 = 4.4729195340508E+01 R2 = 1.0925768920430E-08 DASKR-- NONLINEAR SYSTEM SOLVER COULD NOT CONVERGE DASKR-- BECAUSE IRES WAS EQUAL TO MINUS ONE LOG_STDOUT | warning | A Modelica assert prevents the integrator to continue. For more information use -lv LOG_SOLVER LOG_STDOUT | warning | can't continue. time = 44.729195 LOG_ASSERT | debug | Solving non-linear system 2411 failed at time=44.7291953405079. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 44.7292