startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 wasm-jit simulation: simulate(IDEAS.Fluid.HeatPumps.Examples.HeatPump_WaterWater,startTime=0,stopTime=1000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="IDEAS_dev_IDEAS.Fluid.HeatPumps.Examples.HeatPump_WaterWater",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWater.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWater.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWater.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump3.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWater.pump3: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump4.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWater.pump4: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump5.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWater.pump5: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump6.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWater.pump6: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump7.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWater.pump7: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.5979e-05s [ 0.0%] pre-initialization | | | | | | 0.0265958s [ 23.8%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.0144944s [ 13.0%] solver (excl. callbacks) | | | | | | 0.0102618s [ 9.2%] creating output-file | | | | | | 0.0196224s [ 17.6%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0406892s [ 36.4%] simulation | | | | | | 0.11169s [100.0%] total | | | | | events | | | | | | 109 state events | | | | | | 3 time events | | | | | solver: dassl | | | | | | 3852 steps taken | | | | | | 4860 calls of functionODE | | | | | | 1443 evaluations of jacobian | | | | | | 79 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0071355s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.