startTime=0 stopTime=10000 tolerance=1e-06 numberOfIntervals=2500 stepSize=4 wasm-jit simulation: simulate(IDEAS.Fluid.HeatExchangers.Examples.EmbeddedPipeDp,startTime=0,stopTime=10000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="IDEAS_IDEAS.Fluid.HeatExchangers.Examples.EmbeddedPipeDp",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | Sparsity pattern for non-linear system 0 is not regular. This indicates that something went wrong during sparsity pattern generation. Removing sparsity pattern and disabling NLS scaling. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 4.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in EmbeddedPipeDp.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 4536.000000 | | | | ((pump.motSpe.y >= 0.0 and pump.motSpe.y <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= pump.motSpe.y <= 1e5, has value: -8.69807e-10" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.8463e-05s [ 0.6%] pre-initialization | | | | | | 0.000115287s [ 1.8%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00133123s [ 21.2%] solver (excl. callbacks) | | | | | | 0.000312259s [ 5.0%] creating output-file | | | | | | 0.000614282s [ 9.8%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00386695s [ 61.6%] simulation | | | | | | 0.00627847s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 363 steps taken | | | | | | 525 calls of functionODE | | | | | | 101 evaluations of jacobian | | | | | | 16 error test failures | | | | | | 7 convergence test failures | | | | | | 0.000150159s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.