startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 wasm-jit simulation: simulate(IDEAS.Fluid.Chillers.Examples.Carnot_TEva,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="IDEAS_IDEAS.Fluid.Chillers.Examples.Carnot_TEva",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | Sparsity pattern for non-linear system 0 is not regular. This indicates that something went wrong during sparsity pattern generation. Removing sparsity pattern and disabling NLS scaling. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.6788e-05s [ 1.4%] pre-initialization | | | | | | 0.000102744s [ 3.0%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000222754s [ 6.5%] creating output-file | | | | | | 9.087e-06s [ 0.3%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00305602s [ 88.9%] simulation | | | | | | 0.00343739s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 2502 steps taken | | | | | | 2502 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.