startTime=432000 stopTime=864000 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.IdealHeatingCoolingWinter,startTime=432000,stopTime=864000,tolerance=1e-07,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|flo.TAirCor|flo.TAirSou|flo.TAirNor|flo.TAirEas|flo.TAirWes|hea.[0-9,]+..conPID.y|flo.sou.heaPorAir.Q_flow|flo.eas.heaPorAir.Q_flow|flo.nor.heaPorAir.Q_flow|flo.wes.heaPorAir.Q_flow|flo.cor.heaPorAir.Q_flow|EHea.y|ECoo.y|coo.[0-9,]+..conPID.y",fileNamePrefix="Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.IdealHeatingCoolingWinter",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_STDOUT | warning | Sparsity pattern for non-linear system 1 is not regular. This indicates that something went wrong during sparsity pattern generation. Removing sparsity pattern and disabling NLS scaling. EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.10.06 19:39 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/06/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 9.037e-05s [ 0.0%] pre-initialization | | | | | | 5.6471s [ 75.3%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.141037s [ 1.9%] solver (excl. callbacks) | | | | | | 0.00248827s [ 0.0%] creating output-file | | | | | | 0.488996s [ 6.5%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 1.21907s [ 16.3%] simulation | | | | | | 7.49878s [100.0%] total | | | | | events | | | | | | 719 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 38319 steps taken | | | | | | 55488 calls of functionODE | | | | | | 9741 evaluations of jacobian | | | | | | 1383 error test failures | | | | | | 424 convergence test failures | | | | | | 0.808792s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 2.14sec EnergyPlus Completed Successfully.