startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.08 wasm-jit simulation: simulate(BuildingSystems.Fluid.Movers.Validation.PowerEuler,startTime=0,stopTime=200,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.Movers.Validation.PowerEuler",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | Sparsity pattern for non-linear system 0 is not regular. This indicates that something went wrong during sparsity pattern generation. Removing sparsity pattern and disabling NLS scaling. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_dp.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in PowerEuler.pump_dp: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump_dp.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump_dp.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in PowerEuler.pump_dp: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_m_flow.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in PowerEuler.pump_m_flow: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump_m_flow.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump_m_flow.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in PowerEuler.pump_m_flow: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 14 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.8651e-05s [ 0.4%] pre-initialization | | | | | | 0.000380868s [ 3.5%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000272938s [ 2.5%] solver (excl. callbacks) | | | | | | 0.000282266s [ 2.6%] creating output-file | | | | | | 0.000591656s [ 5.4%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00938465s [ 85.6%] simulation | | | | | | 0.010961s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 69 steps taken | | | | | | 86 calls of functionODE | | | | | | 54 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000102562s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.