startTime=0 stopTime=86400 tolerance=1e-08 numberOfIntervals=2500 stepSize=34.56 wasm-jit simulation: simulate(BuildingSystems.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator,startTime=0,stopTime=86400,tolerance=1e-08,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | Sparsity pattern for non-linear system 0 is not regular. This indicates that something went wrong during sparsity pattern generation. Removing sparsity pattern and disabling NLS scaling. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaPumSou.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in AirToWater2D_OneRoomRadiator.pumHeaPumSou: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/HeatPumps/ModularReversible/TableData2D.mo:78:3-83:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((abs(heaPum.scaFacHea - heaPum.scaFacCoo) / heaPum.scaFacHea < heaPum.limWarSca)) --> "In AirToWater2D_OneRoomRadiator.heaPum: Scaling factors for heating and cooling | | | | operation differ by -17.4444 %. The simulated nominal heating and cooling | | | | capacities may not be realistic for a single device" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.9192e-05s [ 0.0%] pre-initialization | | | | | | 0.0269489s [ 12.6%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.0329349s [ 15.4%] solver (excl. callbacks) | | | | | | 0.00109539s [ 0.5%] creating output-file | | | | | | 0.0458464s [ 21.4%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.107121s [ 50.1%] simulation | | | | | | 0.213996s [100.0%] total | | | | | events | | | | | | 263 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 19739 steps taken | | | | | | 25297 calls of functionODE | | | | | | 5095 evaluations of jacobian | | | | | | 616 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0562737s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.