startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=2500 stepSize=2.88 wasm-jit simulation: simulate(AixLib.Systems.ModularAHU.Examples.GenericAHU,startTime=0,stopTime=7200,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="AixLib_AixLib.Systems.ModularAHU.Examples.GenericAHU",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | warning | Sparsity pattern for non-linear system 0 is not regular. This indicates that something went wrong during sparsity pattern generation. Removing sparsity pattern and disabling NLS scaling. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GenericAHU.genericAHU.fanSup: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GenericAHU.genericAHU.fanRet: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:100:3-100:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.eta, has value: -2.89462e-12" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.heaDis.etaHyd, has value: -4.34644e-09" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.eff.yMot, has value: -3.38214e-14" LOG_SUCCESS | info | The initialization finished successfully with 4 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 14.400000 | | | | ((genericAHU.cooler.hydraulicModule.valve.actPos.y >= 0.0 and genericAHU.cooler.hydraulicModule.valve.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.cooler.hydraulicModule.valve.actPos.y <= 1.0, has value: -1.01011e-29" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 14.400000 | | | | ((genericAHU.heater.hydraulicModule.valve.res3.y >= 0.0 and genericAHU.heater.hydraulicModule.valve.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.heater.hydraulicModule.valve.res3.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 14.400000 | | | | ((genericAHU.heater.hydraulicModule.valve.actPos.y >= 0.0 and genericAHU.heater.hydraulicModule.valve.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.heater.hydraulicModule.valve.actPos.y <= 1.0, has value: -4.68339e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 25.920000 | | | | ((genericAHU.preheater.hydraulicModule.valve.actPos.y >= 0.0 and genericAHU.preheater.hydraulicModule.valve.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.preheater.hydraulicModule.valve.actPos.y <= 1.0, has value: -2.4257e-20" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.5727e-05s [ 0.0%] pre-initialization | | | | | | 0.00266481s [ 2.1%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.0931464s [ 73.5%] solver (excl. callbacks) | | | | | | 0.00222846s [ 1.8%] creating output-file | | | | | | 0s [ 0.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0286857s [ 22.6%] simulation | | | | | | 0.126761s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 453 steps taken | | | | | | 687 calls of functionODE | | | | | | 73 evaluations of jacobian | | | | | | 29 error test failures | | | | | | 4 convergence test failures | | | | | | 0.0130096s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.