startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=3600 stepSize=2 wasm-jit simulation: simulate(AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.DynamicValidation,startTime=0,stopTime=7200,tolerance=1e-06,numberOfIntervals=3600,outputFormat="empty",variableFilter="",fileNamePrefix="AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.DynamicValidation",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_STDOUT | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationEta.txt" LOG_STDOUT | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationOda.txt" LOG_STDOUT | info | ... loading "Result" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/DynamicValidationResult.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DynamicValidation.fan: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in DynamicValidation.fan1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.8271e-05s [ 0.0%] pre-initialization | | | | | | 0.00205874s [ 0.0%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.781413s [ 6.8%] solver (excl. callbacks) | | | | | | 0.0185948s [ 0.2%] creating output-file | | | | | | 0.115984s [ 1.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 10.6095s [ 92.0%] simulation | | | | | | 11.5276s [100.0%] total | | | | | events | | | | | | 676 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 16322 steps taken | | | | | | 33046 calls of functionODE | | | | | | 10006 evaluations of jacobian | | | | | | 938 error test failures | | | | | | 1984 convergence test failures | | | | | | 8.97289s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.