startTime=0 stopTime=25 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.025 wasm-jit simulation: simulate(ThermofluidStream.Examples.WaterHammer,startTime=0,stopTime=25,tolerance=1e-06,numberOfIntervals=1000,outputFormat="mat",variableFilter="Time|checkValve.inlet.m_flow|firstOrder.y|pulse.T_start|pulse.count|reservoir.M|reservoir.U_med|source.outlet.m_flow",fileNamePrefix="ThermofluidStream_ThermofluidStream.Examples.WaterHammer",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Boundaries/Internal/PartialVolume.mo:114:3-114:138:writable] | | | | The following assertion has been violated at time 7.425000 | | | | ((checkValve.inlet.m_flow > reservoir.m_flow_assert)) --> "In "WaterHammer.reservoir": Negative mass flow rate at Volume inlet" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 1.9657e-05s [ 0.1%] pre-initialization | | | | | | 3.4294e-05s [ 0.2%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00549744s [ 25.3%] solver (excl. callbacks) | | | | | | 0.000122341s [ 0.6%] creating output-file | | | | | | 0.00224731s [ 10.4%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0137863s [ 63.5%] simulation | | | | | | 0.0217073s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 49 time events | | | | | solver: dassl | | | | | | 9221 steps taken | | | | | | 16415 calls of functionODE | | | | | | 2109 evaluations of jacobian | | | | | | 676 error test failures | | | | | | 77 convergence test failures | | | | | | 0.0030243s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.