startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2513 stepSize=240.669 wasm-jit simulation: simulate(Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ6,startTime=0,stopTime=604800,tolerance=1e-06,numberOfIntervals=2513,outputFormat="mat",variableFilter="time|bui.maxTSet.[0-9,]+..y|bui.minTSet.[0-9,]+..y|bui.znAttic.TAir|bui.znCore_ZN.TAir|bui.znPerimeter_ZN_1.TAir|bui.znPerimeter_ZN_2.TAir|bui.znPerimeter_ZN_3.TAir|bui.znPerimeter_ZN_4.TAir|bui.terUni.[0-9,]+..QActHea_flow|bui.terUni.[0-9,]+..QActCoo_flow|supHeaWat.T_in|bui.terUni.[0-9,]+..T_aHeaWat_nominal|bui.disFloHea.mAct_flow.[0-9,]+..y|supChiWat.T_in|bui.terUni.[0-9,]+..T_aChiWat_nominal|bui.disFloCoo.mAct_flow.[0-9,]+..y",fileNamePrefix="Buildings_12_Buildings.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ6",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.10.06 17:09 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | debug | /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Utilities/Psychrometrics/Functions/sublimationPressureIce.mo:16: Invalid root: (-0.479412)^(-1.5) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 386032.311978 | | | | ((bui.terUni[2].hexWetNtu.SHR >= 0.0 and bui.terUni[2].hexWetNtu.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.terUni[2].hexWetNtu.SHR <= 1.0, has value: -0.890052" Updating Shadowing Calculations, Start Date=01/08/2006 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 8.7923e-05s [ 0.0%] pre-initialization | | | | | | 6.80067s [ 51.2%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.251507s [ 1.9%] solver (excl. callbacks) | | | | | | 0.0173373s [ 0.1%] creating output-file | | | | | | 0.885598s [ 6.7%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 5.32578s [ 40.1%] simulation | | | | | | 13.281s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 1007 time events | | | | | solver: dassl | | | | | | 63655 steps taken | | | | | | 83115 calls of functionODE | | | | | | 9608 evaluations of jacobian | | | | | | 995 error test failures | | | | | | 9 convergence test failures | | | | | | 3.31585s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 6.80sec EnergyPlus Completed Successfully.