startTime=1.87488e+07 stopTime=1.93536e+07 tolerance=1e-06 numberOfIntervals=2513 stepSize=240.669 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer,startTime=1.87488e+07,stopTime=1.93536e+07,tolerance=1e-06,numberOfIntervals=2513,outputFormat="mat",variableFilter="time|zon.TAir|equEle.y",fileNamePrefix="Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2026.10.06 16:53 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/21/2017 Continuing Simulation at 01/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/10/2017 Continuing Simulation at 02/10/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/02/2017 Continuing Simulation at 03/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/22/2017 Continuing Simulation at 03/22/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/11/2017 Continuing Simulation at 04/11/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/01/2017 Continuing Simulation at 05/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/21/2017 Continuing Simulation at 05/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/10/2017 Continuing Simulation at 06/10/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/30/2017 Continuing Simulation at 06/30/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=07/20/2017 Continuing Simulation at 07/20/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output OneZoneOneOutputVariableSummer.equEle.y has in Modelica the unit 1. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 18748800.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. Updating Shadowing Calculations, Start Date=08/09/2017 Continuing Simulation at 08/09/2017 for SPAWN-RUNPERIOD LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 7.7064e-05s [ 0.0%] pre-initialization | | | | | | 9.46532s [ 96.9%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00954893s [ 0.1%] solver (excl. callbacks) | | | | | | 0.00106857s [ 0.0%] creating output-file | | | | | | 0.216753s [ 2.2%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0761941s [ 0.8%] simulation | | | | | | 9.76896s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 1007 time events | | | | | solver: dassl | | | | | | 16085 steps taken | | | | | | 20287 calls of functionODE | | | | | | 11874 evaluations of jacobian | | | | | | 43 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0137389s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 3.21sec EnergyPlus Completed Successfully.