startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 wasm-jit simulation: simulate(Buildings.DHC.Plants.Combined.Subsystems.Validation.CoolingTowerGroup,startTime=0,stopTime=1000,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|y1.y.[0-9,]+.|ctl.y|coo.m_flow|coo.coo.m_flow|coo.mConWatUni_flow_nominal|coo.weaBus.TWetBul|TConWatSupSet.y|TConWatRet.T|TConWatSup.T|coo.P",fileNamePrefix="Buildings_11_Buildings.DHC.Plants.Combined.Subsystems.Validation.CoolingTowerGroup",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 97.600000 | | | | ((coo.coo.m_flow >= 0.0 and coo.coo.m_flow <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= coo.coo.m_flow <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 895.200000 | | | | ((pum.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pum.etaHyd, has value: -8.60551e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 986.000000 | | | | ((pum.pum.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pum.eff.yMot, has value: -2.28833e-34" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.3083e-05s [ 0.0%] pre-initialization | | | | | | 0.0315521s [ 58.8%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000773263s [ 1.4%] solver (excl. callbacks) | | | | | | 0.000538511s [ 1.0%] creating output-file | | | | | | 0.000862731s [ 1.6%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0199351s [ 37.1%] simulation | | | | | | 0.0536847s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 5 time events | | | | | solver: dassl | | | | | | 493 steps taken | | | | | | 595 calls of functionODE | | | | | | 116 evaluations of jacobian | | | | | | 16 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00128139s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.