startTime=0 stopTime=2 tolerance=1e-09 numberOfIntervals=2500 stepSize=0.0008 wasm-jit simulation: simulate(BuildingSystems.Fluid.MixingVolumes.Validation.MixingVolume,startTime=0,stopTime=2,tolerance=1e-09,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Fluid.MixingVolumes.Validation.MixingVolume",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.3033e-05s [ 0.3%] pre-initialization | | | | | | 5.3881e-05s [ 0.8%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00110359s [ 16.1%] solver (excl. callbacks) | | | | | | 0.000476528s [ 7.0%] creating output-file | | | | | | 0.000957573s [ 14.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00422111s [ 61.8%] simulation | | | | | | 0.00683572s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 363 steps taken | | | | | | 515 calls of functionODE | | | | | | 94 evaluations of jacobian | | | | | | 15 error test failures | | | | | | 0 convergence test failures | | | | | | 7.4923e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.