startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.002 wasm-jit simulation: simulate(TAeZoSysPro_testsuite.HeatTransfer.BaseClasses.test_FreeConvection,startTime=0,stopTime=1,tolerance=1e-06,numberOfIntervals=500,outputFormat="empty",variableFilter="",fileNamePrefix="TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.HeatTransfer.BaseClasses.test_FreeConvection",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/horizontal_cylinder_ASHRAE.mo:15:3-15:126:writable] | | | | the Rayleigh number <10^9 is out of the range of the correlation LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/Functions/FreeConvection/vertical_plate_ASHRAE.mo:20:3-20:157:writable] | | | | the Rayleigh number < 10^9 is out of the range of the correlation. => Correlation extrapolated LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 1.8154e-05s [ 2.2%] pre-initialization | | | | | | 0.000102423s [ 12.4%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000603614s [ 73.1%] solver (excl. callbacks) | | | | | | 4.7683e-05s [ 5.8%] creating output-file | | | | | | 0s [ 0.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 5.4063e-05s [ 6.5%] simulation | | | | | | 0.000825937s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 27 steps taken | | | | | | 27 calls of functionODE | | | | | | 26 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 1.4848e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.