startTime=-172800 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=103.68 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.RunPeriod.NegativeStartTime,startTime=-172800,stopTime=86400,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|zon.TAir|building.weaBus.TDryBul|sitDirSol.y|building.weaBus.HDirNor|sitOutDryBul.y",fileNamePrefix="Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.RunPeriod.NegativeStartTime",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.10.05 16:30 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 12/30/2005 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output NegativeStartTime.sitDirSol.y has in Modelica the unit W/m2. LOG_STDOUT | info | Output NegativeStartTime.sitOutDryBul.y has in Modelica the unit K. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time -172800.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 5.268e-05s [ 0.0%] pre-initialization | | | | | | 5.3647s [ 97.3%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00594411s [ 0.1%] solver (excl. callbacks) | | | | | | 0.000768548s [ 0.0%] creating output-file | | | | | | 0.105292s [ 1.9%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0389157s [ 0.7%] simulation | | | | | | 5.51567s [100.0%] total | | | | | events | | | | | | 431 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 6492 steps taken | | | | | | 7742 calls of functionODE | | | | | | 5439 evaluations of jacobian | | | | | | 11 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00998347s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.30sec EnergyPlus Completed Successfully.