Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Bodylight_Bodylight.SteadyStates.Examples.ThermalBody_QHP_STeadyState.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "[:1:22-1:33:writable] Warning: Modelica only supports 32-bit signed integers! Transforming: 13743895347 into a real Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0002091/0.0002091, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0001781/0.0001781, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.1004/0.1004, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Bodylight 1.1.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Bodylight 1.1.0/package.mo): time 0.003824/0.003824, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 180] Using package Bodylight with version 1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Bodylight 1.1.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: simulate(Bodylight.SteadyStates.Examples.ThermalBody_QHP_STeadyState,startTime=0,stopTime=1,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Bodylight_Bodylight.SteadyStates.Examples.ThermalBody_QHP_STeadyState",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") simulate(Bodylight.SteadyStates.Examples.ThermalBody_QHP_STeadyState,startTime=0,stopTime=1,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="Bodylight_Bodylight.SteadyStates.Examples.ThermalBody_QHP_STeadyState",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") [Timeout 900] "Notification: Performance of FrontEnd - loaded program: time 1.332e-06/1.332e-06, allocations: 0 / 0, free: 0 / 0 Notification: Performance of FrontEnd - Absyn->SCode: time 2.241e-05/2.374e-05, allocations: 0 / 0, free: 0 / 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Bodylight 1.1.0/SteadyStates.mo:783:14-783:57:writable] Error: Modified element Simulation not found in class HeatAccumulation. Notification: Performance of FrontEnd: time 0.0008808/0.0009045, allocations: 0 / 0, free: 0 / 0 " [Timeout remaining time 900] [Calling sys.exit(0), Time elapsed: 0.5267111537978053]