startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=173 stepSize=499.422 wasm-jit simulation: simulate(AixLib.Fluid.Examples.GeothermalHeatPump.GeothermalHeatPump,startTime=0,stopTime=86400,tolerance=1e-06,numberOfIntervals=173,outputFormat="empty",variableFilter="",fileNamePrefix="AixLib_AixLib.Fluid.Examples.GeothermalHeatPump.GeothermalHeatPump",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpColdConsumer.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpColdConsumer: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpHeatConsumer.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpHeatConsumer: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpCondenser.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpCondenser: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpEvaporator.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpEvaporator: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpGeothermalSource.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpGeothermalSource: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/FixedResistances/BaseClasses/PlugFlowHeatLoss.mo:30:3-31:48:writable] | | | | The following assertion has been violated at time 15482.080925 | | | | ((heatStorage.heatingCoil1.pipe[1].heaLos_a.T_a_inflow >= 0.0)) --> "Variable violating min constraint: 0.0 <= heatStorage.heatingCoil1.pipe[1].heaLos_a.T_a_inflow, has value: -157.428" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/FixedResistances/BaseClasses/PlugFlowHeatLoss.mo:32:3-33:49:writable] | | | | The following assertion has been violated at time 15482.080925 | | | | ((heatStorage.heatingCoil1.pipe[1].heaLos_a.T_b_outflow >= 0.0)) --> "Variable violating min constraint: 0.0 <= heatStorage.heatingCoil1.pipe[1].heaLos_a.T_b_outflow, has value: -157.428" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.5498e-05s [ 0.0%] pre-initialization | | | | | | 0.000834251s [ 0.0%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.528194s [ 13.3%] solver (excl. callbacks) | | | | | | 0.00156155s [ 0.0%] creating output-file | | | | | | 0.66188s [ 16.7%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 2.78045s [ 70.0%] simulation | | | | | | 3.97295s [100.0%] total | | | | | events | | | | | | 332 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 31055 steps taken | | | | | | 50049 calls of functionODE | | | | | | 9364 evaluations of jacobian | | | | | | 3049 error test failures | | | | | | 446 convergence test failures | | | | | | 1.87784s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.