startTime=0 stopTime=50 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.02 wasm-jit simulation: simulate(ThermoPower.Test.WaterComponents.TestBarometricCondenser,startTime=0,stopTime=50,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="ThermoPower_4.0.0-dev_ThermoPower.Test.WaterComponents.TestBarometricCondenser",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.0218e-05s [ 0.1%] pre-initialization | | | | | | 0.00324815s [ 11.9%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000355089s [ 1.3%] solver (excl. callbacks) | | | | | | 0.000310027s [ 1.1%] creating output-file | | | | | | 0.000616209s [ 2.3%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0227803s [ 83.4%] simulation | | | | | | 0.02733s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 173 steps taken | | | | | | 205 calls of functionODE | | | | | | 71 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000856396s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.