startTime=0 stopTime=10 tolerance=1e-08 numberOfIntervals=2500 stepSize=0.004 wasm-jit simulation: simulate(OpenHydraulics.DevelopmentTests.DoubleActingCylinderTestSimple2,startTime=0,stopTime=10,tolerance=1e-08,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="OpenHydraulics_OpenHydraulics.DevelopmentTests.DoubleActingCylinderTestSimple2",simflags="-abortSlowSimulation -alarm=240 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | | | | | WARNING: CylinderChamber has reached end of travel. LOG_STDOUT | info | This could cause erratic behavior of the simulation. LOG_STDOUT | info | (time = 3.84674) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics main/Components/Cylinders/BaseClasses/CylinderCushion.mo:29:3-29:77:writable] | | | | The following assertion has been violated at time 3.846744 | | | | ((doubleActingCylinder.cushionRod.s_rel >= 0.0)) --> "Variable violating min constraint: 0.0 <= doubleActingCylinder.cushionRod.s_rel, has value: -1.00006e-12" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.4727e-05s [ 0.1%] pre-initialization | | | | | | 0.000109336s [ 0.4%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00784211s [ 27.8%] solver (excl. callbacks) | | | | | | 0.000361679s [ 1.3%] creating output-file | | | | | | 0.00580715s [ 20.6%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0140291s [ 49.8%] simulation | | | | | | 0.0281741s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 7490 steps taken | | | | | | 10899 calls of functionODE | | | | | | 893 evaluations of jacobian | | | | | | 247 error test failures | | | | | | 106 convergence test failures | | | | | | 0.0027575s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.