startTime=0 stopTime=315710 tolerance=1e-06 numberOfIntervals=126789 stepSize=2.49004 wasm-jit simulation: simulate(Buildings.Utilities.Plotters.Examples.ControlsVerification_CoolingCoilValve,startTime=0,stopTime=315710,tolerance=1e-06,numberOfIntervals=126789,outputFormat="mat",variableFilter="time|cooValSta.TSup|cooValSta.TSupSet|cooValSta.TOut|cooValSta.uFanFee|cooValSta.uFanSta|percConv.y|cooValSta.yCooVal",fileNamePrefix="Buildings_latest_Buildings.Utilities.Plotters.Examples.ControlsVerification_CoolingCoilValve",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_STDOUT | info | ... loading "Supply_Air_Temp" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/Supply_Air_Temp.mos" LOG_STDOUT | info | ... loading "VFD_Fan_Enable" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/VFD_Fan_Enable.mos" LOG_STDOUT | info | ... loading "VFD_Fan_Feedback" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/VFD_Fan_Feedback.mos" LOG_STDOUT | info | ... loading "Clg_Coil_Valve" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/Clg_Coil_Valve.mos" LOG_STDOUT | info | ... loading "SA_Clg_Stpt" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/SA_Clg_Stpt.mos" LOG_STDOUT | info | ... loading "OA_Temp" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/OA_Temp.mos" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.6209e-05s [ 0.0%] pre-initialization | | | | | | 0.108908s [ 4.4%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.280904s [ 11.4%] solver (excl. callbacks) | | | | | | 0.0776907s [ 3.2%] creating output-file | | | | | | 1.023s [ 41.6%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.968212s [ 39.4%] simulation | | | | | | 2.45874s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 63143 time events | | | | | solver: dassl | | | | | | 834917 steps taken | | | | | | 909348 calls of functionODE | | | | | | 778019 evaluations of jacobian | | | | | | 17165 error test failures | | | | | | 0 convergence test failures | | | | | | 0.180437s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. LOG_STDOUT | info | Wrote plot file "coolingCoilValve_validationPlots.html".