startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 wasm-jit simulation: simulate(Buildings.Airflow.Multizone.Examples.ChimneyShaftWithVolume,startTime=0,stopTime=3600,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|roo.T|bou0.T|sha.vol.T|oriChiTop.m_flow|oriBot.m_flow|oriChiBot.m_flow|con.u_s|con.u_m|con.y",fileNamePrefix="Buildings_latest_Buildings.Airflow.Multizone.Examples.ChimneyShaftWithVolume",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Airflow/Multizone/BaseClasses/PartialOneWayFlowElement.mo:39:3-40:61:writable] | | | | The following assertion has been violated at time 0.229847 | | | | ((oriChiTop.mExc >= 0.0)) --> "Variable violating min constraint: 0.0 <= oriChiTop.mExc, has value: -0.0062573" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Airflow/Multizone/BaseClasses/PartialOneWayFlowElement.mo:39:3-40:61:writable] | | | | The following assertion has been violated at time 0.229847 | | | | ((oriChiBot.mExc >= 0.0)) --> "Variable violating min constraint: 0.0 <= oriChiBot.mExc, has value: -0.00563175" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Airflow/Multizone/BaseClasses/PartialOneWayFlowElement.mo:39:3-40:61:writable] | | | | The following assertion has been violated at time 1.440000 | | | | ((oriBot.mExc >= 0.0)) --> "Variable violating min constraint: 0.0 <= oriBot.mExc, has value: -0.02111" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.3715e-05s [ 0.4%] pre-initialization | | | | | | 0.000125045s [ 2.2%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000780457s [ 13.9%] solver (excl. callbacks) | | | | | | 0.000264765s [ 4.7%] creating output-file | | | | | | 0.0010017s [ 17.8%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00342574s [ 60.9%] simulation | | | | | | 0.00562141s [100.0%] total | | | | | events | | | | | | 15 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 373 steps taken | | | | | | 590 calls of functionODE | | | | | | 139 evaluations of jacobian | | | | | | 14 error test failures | | | | | | 3 convergence test failures | | | | | | 0.000162612s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.