startTime=432000 stopTime=864000 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 wasm-jit simulation: simulate(Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Winter,startTime=432000,stopTime=864000,tolerance=1e-07,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|flo.sou.TAir|flo.eas.TAir|flo.nor.TAir|flo.wes.TAir|flo.cor.TAir|hvac.TSetRoo.setPoiHea.y|hvac.TSetRoo.setPoiCoo.y|hvac.fanSup.y|hvac.VAVBox.[0-9,]+..vav.y_actual|hvac.damOut.y|hvac.VAVBox.[0-9,]+..TSup|hvac.res.EFan|hvac.res.EHea|hvac.res.ECoo",fileNamePrefix="Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Winter",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.10.05 13:40 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/06/2006 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 432000.000000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -3.2842e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 432000.000000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -2.92234e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 432000.000000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -3.2842e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 432000.000000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -2.92234e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 432000.000000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -4.33235e-13" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 432112.526351 | | | | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -1.3046e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 432112.526351 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -3.21608e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 500428.800000 | | | | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -1.08306e-40" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 500601.600000 | | | | ((hvac.pumHeaCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -1.50393e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 500601.600000 | | | | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -1.3373e-26" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 500947.200000 | | | | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 1e5, has value: -2.82489e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 501000.000005 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -3.63784e-128" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Utilities/Psychrometrics/TDewPoi_pW.mo:5:3-9:74:writable] | | | | The following assertion has been violated at time 540020.161528 | | | | ((hvac.cooCoi.dryWetCalcs.TDewIn.p_w >= 100.0)) --> "Variable violating min constraint: 100.0 <= hvac.cooCoi.dryWetCalcs.TDewIn.p_w, has value: 87.6145" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 6.0324e-05s [ 0.0%] pre-initialization | | | | | | 5.52801s [ 25.2%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.772325s [ 3.5%] solver (excl. callbacks) | | | | | | 0.00521128s [ 0.0%] creating output-file | | | | | | 2.05421s [ 9.4%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 13.6017s [ 61.9%] simulation | | | | | | 21.9616s [100.0%] total | | | | | events | | | | | | 793 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 49458 steps taken | | | | | | 81642 calls of functionODE | | | | | | 25604 evaluations of jacobian | | | | | | 2319 error test failures | | | | | | 4041 convergence test failures | | | | | | 11.7054s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 16.69sec EnergyPlus Completed Successfully.