startTime=0 stopTime=0.1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.0002 wasm-jit simulation: simulate(Modelica.Electrical.PowerConverters.Examples.DCAC.SinglePhaseTwoLevel.SinglePhaseTwoLevel_RL,startTime=0,stopTime=0.1,tolerance=1e-06,numberOfIntervals=500,outputFormat="mat",variableFilter="time|inductor.i|fundamentalWaveCurrent.mean1.y|fundamentalWaveCurrent.mean2.y|fundamentalWaveVoltage.mean1.y|fundamentalWaveVoltage.mean2.y|inverter.ac.v|inverter.ac.i",fileNamePrefix="Modelica_4.0.0_Modelica.Electrical.PowerConverters.Examples.DCAC.SinglePhaseTwoLevel.SinglePhaseTwoLevel_RL",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.0677e-05s [ 0.1%] pre-initialization | | | | | | 0.000106891s [ 0.2%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00403561s [ 8.9%] solver (excl. callbacks) | | | | | | 0.000165032s [ 0.4%] creating output-file | | | | | | 0.0200464s [ 44.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0212074s [ 46.5%] simulation | | | | | | 0.045592s [100.0%] total | | | | | events | | | | | | 206 state events | | | | | | 101 time events | | | | | solver: dassl | | | | | | 10184 steps taken | | | | | | 7897 calls of functionODE | | | | | | 1985 evaluations of jacobian | | | | | | 11 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00355132s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.