startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 wasm-jit simulation: simulate(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,startTime=0,stopTime=172800,tolerance=1e-06,numberOfIntervals=2500,outputFormat="mat",variableFilter="time|roo.weaBus.TDryBul|roo.air.vol.T",fileNamePrefix="Buildings_11_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/HeatTransfer/Windows/BaseClasses/ShadeInterface_weatherBus.mo:26:3-30:70:writable] | | | | The following assertion has been violated at time 27509.760000 | | | | ((roo.bouConExtWin.sha[1].fraSun >= 0.0 and roo.bouConExtWin.sha[1].fraSun <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= roo.bouConExtWin.sha[1].fraSun <= 1.0, has value: 1.00004" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Routing.mo:453:5-455:43:writable] | | | | The following assertion has been violated at time 27509.760000 | | | | ((roo.bouConExtWin.sha[1].mulFraSun.y[1] >= 0.0 and roo.bouConExtWin.sha[1].mulFraSun.y[1] <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= roo.bouConExtWin.sha[1].mulFraSun.y[1] <= 1.0, has value: 1.00004" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.3414e-05s [ 0.0%] pre-initialization | | | | | | 0.0268275s [ 56.9%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000710079s [ 1.5%] solver (excl. callbacks) | | | | | | 0.000785104s [ 1.7%] creating output-file | | | | | | 0.000602551s [ 1.3%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0182227s [ 38.6%] simulation | | | | | | 0.0471713s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 22 steps taken | | | | | | 22 calls of functionODE | | | | | | 21 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00235784s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.