Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.4556/0.4556, allocations: 111.6 MB / 131.4 MB, free: 4.438 MB / 122.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin") translateModel(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.813e-06/1.813e-06, allocations: 3.938 kB / 176.5 MB, free: 8.941 MB / 170.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.065e-05/1.246e-05, allocations: 2.312 kB / 176.5 MB, free: 8.938 MB / 170.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin): time 1.006/1.006, allocations: 261.3 MB / 437.9 MB, free: 11.95 MB / 394.7 MB Notification: Performance of NFInst.instExpressions: time 0.2837/1.29, allocations: 145.6 MB / 0.5698 GB, free: 1.035 MB / 490.7 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0005943/1.291, allocations: 12 kB / 0.5698 GB, free: 1.023 MB / 490.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SourcePQ.mo:15:3-16:78:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/Sink.mo:12:3-13:80:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:36:3-37:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:38:3-39:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:40:3-41:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:44:3-45:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:11:3-12:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:13:3-14:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:11:3-12:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:13:3-14:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:32:3-33:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:34:3-35:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:17:3-18:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:19:3-20:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:36:3-37:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:42:3-43:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:44:3-45:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:11:3-12:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:13:3-14:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:11:3-12:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:13:3-14:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:32:3-33:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:34:3-35:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:17:3-18:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:19:3-20:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:17:3-18:81:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:19:3-20:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:21:3-22:79:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:38:3-39:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:40:3-41:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:42:3-43:78:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0005169/1.291, allocations: 213.8 kB / 0.57 GB, free: 0.8125 MB / 490.7 MB Notification: Performance of NFTyping.typeBindings: time 0.0008066/1.292, allocations: 0.5165 MB / 0.5705 GB, free: 300 kB / 490.7 MB Notification: Performance of NFTyping.typeClassSections: time 0.002567/1.294, allocations: 1.538 MB / 0.572 GB, free: 14.75 MB / 0.4948 GB Notification: Performance of NFFlatten.flatten: time 0.001844/1.296, allocations: 2.435 MB / 0.5744 GB, free: 12.31 MB / 0.4948 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001182/1.297, allocations: 1.066 MB / 0.5754 GB, free: 11.2 MB / 0.4948 GB Notification: Performance of NFEvalConstants.evaluate: time 0.001236/1.299, allocations: 1.365 MB / 0.5768 GB, free: 9.836 MB / 0.4948 GB Notification: Performance of NFSimplifyModel.simplify: time 0.0006757/1.299, allocations: 0.7713 MB / 0.5775 GB, free: 9.062 MB / 0.4948 GB Notification: Performance of NFPackage.collectConstants: time 0.0002219/1.3, allocations: 240 kB / 0.5777 GB, free: 8.828 MB / 0.4948 GB Notification: Performance of NFFlatten.collectFunctions: time 0.001569/1.301, allocations: 1.122 MB / 0.5788 GB, free: 7.703 MB / 0.4948 GB Notification: Performance of NFScalarize.scalarize: time 0.0002771/1.301, allocations: 0.5141 MB / 0.5793 GB, free: 7.188 MB / 0.4948 GB Notification: Performance of NFVerifyModel.verify: time 0.0005482/1.302, allocations: 0.7328 MB / 0.5801 GB, free: 6.453 MB / 0.4948 GB Notification: Performance of NFConvertDAE.convert: time 0.002172/1.304, allocations: 2.196 MB / 0.5822 GB, free: 4.25 MB / 0.4948 GB Notification: Performance of FrontEnd - DAE generated: time 4.509e-06/1.304, allocations: 4 kB / 0.5822 GB, free: 4.246 MB / 0.4948 GB Notification: Performance of FrontEnd: time 1.362e-06/1.304, allocations: 0 / 0.5822 GB, free: 4.246 MB / 0.4948 GB Notification: Performance of Transformations before backend: time 2.737e-05/1.304, allocations: 0 / 0.5822 GB, free: 4.246 MB / 0.4948 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 508 * Number of variables: 508 Notification: Performance of Generate backend data structure: time 0.00222/1.306, allocations: 2.281 MB / 0.5844 GB, free: 1.918 MB / 0.4948 GB Notification: Performance of prepare preOptimizeDAE: time 3.83e-05/1.306, allocations: 11.98 kB / 0.5844 GB, free: 1.906 MB / 0.4948 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0003259/1.307, allocations: 387.7 kB / 0.5848 GB, free: 1.527 MB / 0.4948 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.0006299/1.307, allocations: 0.6906 MB / 0.5855 GB, free: 0.8086 MB / 0.4948 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001072/1.307, allocations: 204.3 kB / 0.5857 GB, free: 0.5977 MB / 0.4948 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0002471/1.308, allocations: 227.8 kB / 0.5859 GB, free: 384 kB / 0.4948 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.001515/1.309, allocations: 1.922 MB / 0.5878 GB, free: 14.21 MB / 0.5105 GB Notification: Performance of preOpt findStateOrder (simulation): time 2.705e-05/1.309, allocations: 11.94 kB / 0.5878 GB, free: 14.2 MB / 0.5105 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 9.712e-05/1.309, allocations: 84 kB / 0.5879 GB, free: 14.11 MB / 0.5105 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 2.726e-05/1.309, allocations: 52 kB / 0.5879 GB, free: 14.06 MB / 0.5105 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.001245/1.311, allocations: 0.9123 MB / 0.5888 GB, free: 13.14 MB / 0.5105 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.007969/1.319, allocations: 10.28 MB / 0.5989 GB, free: 2.57 MB / 0.5105 GB Notification: Performance of preOpt comSubExp (simulation): time 0.0008328/1.319, allocations: 0.6327 MB / 0.5995 GB, free: 1.918 MB / 0.5105 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.0004934/1.32, allocations: 401.1 kB / 0.5999 GB, free: 1.516 MB / 0.5105 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0004181/1.32, allocations: 244.1 kB / 0.6001 GB, free: 1.309 MB / 0.5105 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.0006543/1.321, allocations: 0.5524 MB / 0.6006 GB, free: 0.7344 MB / 0.5105 GB Notification: Performance of pre-optimization done (n=128): time 3.717e-06/1.321, allocations: 0 / 0.6006 GB, free: 0.7344 MB / 0.5105 GB Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default ======================================== 1: volume2S.T Please use -d=bltdump for more information. Notification: Performance of matching and sorting (n=213): time 0.07635/1.397, allocations: 22.68 MB / 0.6228 GB, free: 9.711 MB / 0.5417 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 2.616546385921538]