Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001465/0.001465, allocations: 81.95 kB / 19.87 MB, free: 4.621 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001638/0.001638, allocations: 169.7 kB / 23.28 MB, free: 1.219 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.9459/0.9459, allocations: 177.2 MB / 203.7 MB, free: 5.488 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo): time 0.001694/0.001694, allocations: 242.3 kB / 260.5 MB, free: 12.65 MB / 250.7 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo): time 0.6988/0.6988, allocations: 138.4 MB / 455.5 MB, free: 29.91 MB / 410.7 MB " [Timeout remaining time 179] Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/package.mo) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox") translateModel(BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.173e-06/1.173e-06, allocations: 0 / 0.5555 GB, free: 15.91 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.078e-05/2.195e-05, allocations: 7.609 kB / 0.5555 GB, free: 15.9 MB / 490.7 MB Notification: Performance of NFInst.instantiate(BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox): time 0.3462/0.3462, allocations: 200.6 MB / 0.7514 GB, free: 24.65 MB / 0.5573 GB Notification: Performance of NFInst.instExpressions: time 0.02858/0.3748, allocations: 21.47 MB / 0.7724 GB, free: 6.973 MB / 0.5573 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.009611/0.3844, allocations: 310.9 kB / 0.7727 GB, free: 6.828 MB / 0.5573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/BuildingTemplate.mo:109:3-111:146:writable] Warning: Connector toAmbienceSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/BuildingTemplate.mo:112:3-114:149:writable] Warning: Connector toAmbienceAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfacesToSolids.mo:11:3-13:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ZoneTemplateGeneral.mo:63:3-67:55:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/RadiationDistribution.mo:13:3-15:72:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/AirvolumeGeneral.mo:40:3-41:97:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Ambience.mo:52:3-55:54:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Ambience.mo:56:3-59:53:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Climate/SolarRadiationTransformers/SolarRadiationTransformerGeneral.mo:25:3-27:116:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/Constructions/Shadowing/OverhangElement.mo:4:3-6:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:5:3-7:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:8:3-10:54:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.006858/0.3912, allocations: 2.46 MB / 0.7751 GB, free: 4.812 MB / 0.5573 GB Notification: Performance of NFTyping.typeBindings: time 0.01215/0.4034, allocations: 5.715 MB / 0.7807 GB, free: 140 kB / 0.5573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:8:3-10:54:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:5:3-7:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:8:3-10:54:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:5:3-7:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:8:3-10:54:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:5:3-7:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:8:3-10:54:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Buildings/BaseClasses/ShadowingElementGeneral.mo:5:3-7:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeClassSections: time 0.007491/0.4109, allocations: 3.732 MB / 0.7843 GB, free: 12.96 MB / 0.573 GB Notification: Performance of NFFlatten.flatten: time 0.02476/0.4356, allocations: 29.93 MB / 0.8135 GB, free: 108 kB / 0.5886 GB Notification: Performance of NFFlatten.resolveConnections: time 0.0236/0.4592, allocations: 22.05 MB / 0.8351 GB, free: 9.906 MB / 0.6198 GB Notification: Performance of NFEvalConstants.evaluate: time 0.03165/0.4909, allocations: 22 MB / 0.8566 GB, free: 3.918 MB / 0.6355 GB Notification: Performance of NFSimplifyModel.simplify: time 0.02085/0.5117, allocations: 17.99 MB / 0.8741 GB, free: 1.891 MB / 0.6511 GB Notification: Performance of NFPackage.collectConstants: time 0.01117/0.5229, allocations: 5.148 MB / 0.8792 GB, free: 12.74 MB / 0.6667 GB Notification: Performance of NFFlatten.collectFunctions: time 0.01433/0.5372, allocations: 6.166 MB / 0.8852 GB, free: 6.574 MB / 0.6667 GB Notification: Performance of NFScalarize.scalarize: time 0.01222/0.5495, allocations: 11.09 MB / 0.896 GB, free: 11.46 MB / 0.6823 GB Notification: Performance of NFVerifyModel.verify: time 0.4649/1.014, allocations: 12.61 MB / 0.9083 GB, free: 70.78 MB / 0.6824 GB Notification: Performance of NFConvertDAE.convert: time 0.04271/1.057, allocations: 32.63 MB / 0.9402 GB, free: 68.64 MB / 0.6824 GB Notification: Performance of FrontEnd - DAE generated: time 6.091e-06/1.057, allocations: 0 / 0.9402 GB, free: 68.64 MB / 0.6824 GB Notification: Performance of FrontEnd: time 8.32e-07/1.057, allocations: 0 / 0.9402 GB, free: 68.64 MB / 0.6824 GB Notification: Performance of Transformations before backend: time 0.001499/1.059, allocations: 4.984 kB / 0.9402 GB, free: 68.64 MB / 0.6824 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 6512 * Number of variables: 6512 Notification: Performance of Generate backend data structure: time 0.06426/1.123, allocations: 29.34 MB / 0.9689 GB, free: 59.12 MB / 0.6824 GB Notification: Performance of prepare preOptimizeDAE: time 4.463e-05/1.123, allocations: 10.81 kB / 0.9689 GB, free: 59.12 MB / 0.6824 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02495/1.148, allocations: 5.831 MB / 0.9746 GB, free: 57.67 MB / 0.6824 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.02176/1.17, allocations: 12.04 MB / 0.9863 GB, free: 53.48 MB / 0.6824 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.001379/1.171, allocations: 3.177 MB / 0.9894 GB, free: 51.04 MB / 0.6824 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.008857/1.18, allocations: 2.373 MB / 0.9917 GB, free: 50.27 MB / 0.6824 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.06262/1.242, allocations: 21.54 MB / 1.013 GB, free: 41.8 MB / 0.6824 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0005719/1.243, allocations: 36.47 kB / 1.013 GB, free: 41.78 MB / 0.6824 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.00824/1.251, allocations: 0.9826 MB / 1.014 GB, free: 40.81 MB / 0.6824 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001406/1.253, allocations: 1.243 MB / 1.015 GB, free: 39.57 MB / 0.6824 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.03468/1.287, allocations: 12.75 MB / 1.027 GB, free: 27 MB / 0.6824 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.1422/1.43, allocations: 98.46 MB / 1.124 GB, free: 13.07 MB / 0.7605 GB Notification: Performance of preOpt comSubExp (simulation): time 0.009056/1.439, allocations: 3.947 MB / 1.127 GB, free: 9.348 MB / 0.7605 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.002503/1.441, allocations: 1.213 MB / 1.129 GB, free: 8.168 MB / 0.7605 GB Notification: Performance of preOpt evalFunc (simulation): time 0.001325/1.442, allocations: 0.5309 MB / 1.129 GB, free: 7.656 MB / 0.7605 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.003256/1.446, allocations: 2.49 MB / 1.132 GB, free: 5.141 MB / 0.7605 GB Notification: Performance of pre-optimization done (n=491): time 1.128e-05/1.446, allocations: 0 / 1.132 GB, free: 5.141 MB / 0.7605 GB Notification: Performance of matching and sorting (n=491): time 0.03934/1.485, allocations: 12.87 MB / 1.144 GB, free: 8.348 MB / 0.7762 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0005796/1.486, allocations: 1.083 MB / 1.145 GB, free: 7.027 MB / 0.7762 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.01304/1.499, allocations: 8.825 MB / 1.154 GB, free: 15.52 MB / 0.7918 GB Notification: Performance of collectPreVariables (initialization): time 0.001742/1.5, allocations: 121.7 kB / 1.154 GB, free: 15.4 MB / 0.7918 GB Notification: Performance of collectInitialEqns (initialization): time 0.01013/1.511, allocations: 11.54 MB / 1.165 GB, free: 4.188 MB / 0.7918 GB Notification: Performance of collectInitialBindings (initialization): time 0.003051/1.514, allocations: 1.927 MB / 1.167 GB, free: 2.363 MB / 0.7918 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.008269/1.522, allocations: 3.248 MB / 1.17 GB, free: 15.3 MB / 0.8074 GB Notification: Performance of setup shared object (initialization): time 0.0001038/1.522, allocations: 484.7 kB / 1.171 GB, free: 14.82 MB / 0.8074 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.004346/1.526, allocations: 2.564 MB / 1.173 GB, free: 12.14 MB / 0.8074 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.00742/1.534, allocations: 8.125 MB / 1.181 GB, free: 1.836 MB / 0.8074 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.01512/1.549, allocations: 12.36 MB / 1.193 GB, free: 3.645 MB / 0.823 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001008/1.549, allocations: 32 kB / 1.193 GB, free: 3.613 MB / 0.823 GB Notification: Performance of matching and sorting (n=1215) (initialization): time 0.03106/1.58, allocations: 14.26 MB / 1.207 GB, free: 5.863 MB / 0.8387 GB Notification: Performance of prepare postOptimizeDAE: time 0.0008426/1.581, allocations: 0.6904 MB / 1.208 GB, free: 5.074 MB / 0.8387 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001485/1.581, allocations: 120 kB / 1.208 GB, free: 4.957 MB / 0.8387 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.3268/1.908, allocations: 21.92 MB / 1.229 GB, free: 228.8 MB / 0.8387 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01034/1.918, allocations: 3.784 MB / 1.233 GB, free: 228.8 MB / 0.8387 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.02364/1.942, allocations: 56.9 MB / 1.289 GB, free: 180.6 MB / 0.8387 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.01054/1.952, allocations: 1.315 MB / 1.29 GB, free: 180.6 MB / 0.8387 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.002631/1.955, allocations: 1.016 MB / 1.291 GB, free: 180.6 MB / 0.8387 GB Warning: Assuming fixed start value for the following 21 variables: building.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = 0.0 unit = \"kg\" fixed = true protected = true ) \"Liquid water mass\" type: Real building.wall1.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wall1.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall1.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wall1.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall2.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wall2.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall2.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wall2.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall3.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wall3.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall3.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wall3.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall4.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wall4.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall4.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wall4.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.ceiling.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.ceiling.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.ceiling.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.ceiling.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.bottom.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.bottom.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.bottom.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.bottom.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wallsInterior.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wallsInterior.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wallsInterior.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wallsInterior.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.ceilingsInterior.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.ceilingsInterior.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.ceilingsInterior.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.ceilingsInterior.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.window1.heatTransfer.T:VARIABLE(min = 0.0 start = building.window1.heatTransfer.T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the thermal node\" type: Real building.window2.heatTransfer.T:VARIABLE(min = 0.0 start = building.window2.heatTransfer.T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the thermal node\" type: Real building.window3.heatTransfer.T:VARIABLE(min = 0.0 start = building.window3.heatTransfer.T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the thermal node\" type: Real building.window4.heatTransfer.T:VARIABLE(min = 0.0 start = building.window4.heatTransfer.T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the thermal node\" type: Real Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.01077/1.966, allocations: 3.027 MB / 1.294 GB, free: 179.9 MB / 0.8387 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.00476/1.971, allocations: 8.121 MB / 1.302 GB, free: 172.6 MB / 0.8387 GB Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 0.01045/1.981, allocations: 12.35 MB / 1.314 GB, free: 164.8 MB / 0.8387 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 9.58e-05/1.981, allocations: 37.56 kB / 1.314 GB, free: 164.8 MB / 0.8387 GB Notification: Performance of matching and sorting (n=1215) (initialization_lambda0): time 0.02549/2.007, allocations: 14.25 MB / 1.328 GB, free: 160.9 MB / 0.8387 GB Notification: Performance of prepare postOptimizeDAE: time 0.000482/2.007, allocations: 0.6929 MB / 1.329 GB, free: 160.2 MB / 0.8387 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001399/2.007, allocations: 128 kB / 1.329 GB, free: 160.1 MB / 0.8387 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.04483/2.052, allocations: 21.93 MB / 1.35 GB, free: 141.7 MB / 0.8387 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01005/2.062, allocations: 3.778 MB / 1.354 GB, free: 138.2 MB / 0.8387 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.02382/2.086, allocations: 56.86 MB / 1.409 GB, free: 82.97 MB / 0.8387 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.01062/2.096, allocations: 1.047 MB / 1.41 GB, free: 82.27 MB / 0.8387 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.002554/2.099, allocations: 1.014 MB / 1.411 GB, free: 81.33 MB / 0.8387 GB Warning: Assuming fixed start value for the following 21 variables: building.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = 0.0 unit = \"kg\" fixed = true protected = true ) \"Liquid water mass\" type: Real building.wall1.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wall1.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall1.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wall1.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall2.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wall2.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall2.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wall2.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall3.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wall3.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall3.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wall3.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall4.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wall4.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wall4.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wall4.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.ceiling.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.ceiling.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.ceiling.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.ceiling.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.bottom.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.bottom.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.bottom.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.bottom.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wallsInterior.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.wallsInterior.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.wallsInterior.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.wallsInterior.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.ceilingsInterior.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building.ceilingsInterior.construction.layer[1].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.ceilingsInterior.construction.layer[2].T[1]:VARIABLE(min = 0.0 start = building.ceilingsInterior.construction.layer[2].T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the numerical node\" type: Real [2,1] building.window1.heatTransfer.T:VARIABLE(min = 0.0 start = building.window1.heatTransfer.T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the thermal node\" type: Real building.window2.heatTransfer.T:VARIABLE(min = 0.0 start = building.window2.heatTransfer.T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the thermal node\" type: Real building.window3.heatTransfer.T:VARIABLE(min = 0.0 start = building.window3.heatTransfer.T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the thermal node\" type: Real building.window4.heatTransfer.T:VARIABLE(min = 0.0 start = building.window4.heatTransfer.T_start unit = \"K\" fixed = true nominal = 300.0 ) \"Temperature of the thermal node\" type: Real Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 540 * Number of states: 0 () * Number of discrete variables: 13 (ambience.radiation[1].outsidePolarCircle,ambience.radiation[2].outsidePolarCircle,ambience.radiation[3].outsidePolarCircle,ambience.radiation[4].outsidePolarCircle,ambience.radiation[5].outsidePolarCircle,ambience.radiation[6].outsidePolarCircle,ambience.radiation[7].outsidePolarCircle,radiation.outsidePolarCircle,ambience.weatherDataReader.weatherData.conTim.tNext,$PRE.ambience.weatherDataReader.weatherData.conTim.tNext,$whenCondition1,building.zone.coolingLoad.I.local_reset,building.zone.heatingLoad.I.local_reset) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1066): * Single equations (assignments): 1012 * Array equations: 0 * Algorithm blocks: 16 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 21 * Torn equation systems: 17 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 21 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 8 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 9 systems {(1,3), (15,55), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3)} Notification: Performance of prepare postOptimizeDAE: time 0.002426/2.101, allocations: 1.089 MB / 1.412 GB, free: 80.64 MB / 0.8387 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.002417/2.104, allocations: 1.046 MB / 1.413 GB, free: 79.93 MB / 0.8387 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.0173/2.121, allocations: 8.935 MB / 1.422 GB, free: 72.04 MB / 0.8387 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 4.154e-05/2.121, allocations: 64 kB / 1.422 GB, free: 71.98 MB / 0.8387 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 2.143e-05/2.121, allocations: 12 kB / 1.422 GB, free: 71.96 MB / 0.8387 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.01439/2.136, allocations: 6.645 MB / 1.429 GB, free: 65.56 MB / 0.8387 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.04938/2.185, allocations: 24.3 MB / 1.452 GB, free: 43.33 MB / 0.8387 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 2.539e-05/2.185, allocations: 9.094 kB / 1.452 GB, free: 43.32 MB / 0.8387 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.002935/2.188, allocations: 0.9379 MB / 1.453 GB, free: 42.43 MB / 0.8387 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.04586/2.234, allocations: 22.52 MB / 1.475 GB, free: 19.93 MB / 0.8387 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.001529/2.235, allocations: 175.9 kB / 1.475 GB, free: 19.75 MB / 0.8387 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.3235/2.559, allocations: 54.3 MB / 1.528 GB, free: 225.2 MB / 0.8699 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 8.506e-06/2.559, allocations: 12.31 kB / 1.528 GB, free: 225.2 MB / 0.8699 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.02543/2.584, allocations: 9.819 MB / 1.538 GB, free: 223.5 MB / 0.8699 GB Notification: Performance of postOpt removeConstants (simulation): time 0.006286/2.591, allocations: 2.5 MB / 1.541 GB, free: 223.5 MB / 0.8699 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.002538/2.593, allocations: 146.2 kB / 1.541 GB, free: 223.5 MB / 0.8699 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.00438/2.597, allocations: 258.4 kB / 1.541 GB, free: 223.5 MB / 0.8699 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.001118/2.599, allocations: 468.1 kB / 1.541 GB, free: 223.5 MB / 0.8699 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.000406/2.599, allocations: 155.8 kB / 1.542 GB, free: 223.5 MB / 0.8699 GB Notification: Performance of sorting global known variables: time 0.006349/2.605, allocations: 4.389 MB / 1.546 GB, free: 223.2 MB / 0.8699 GB Notification: Performance of sort global known variables: time 7e-08/2.605, allocations: 2.031 kB / 1.546 GB, free: 223.2 MB / 0.8699 GB Notification: Performance of remove unused functions: time 0.03338/2.639, allocations: 12.53 MB / 1.558 GB, free: 220.3 MB / 0.8699 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 34 * Number of states: 26 (building.zone.airvolume.mH2OLiq,building.zone.airvolume.air.dynBal.U,building.zone.airvolume.air.dynBal.m,building.zone.airvolume.air.dynBal.mXi[1],building.zone.heatingLoad.I.y,building.zone.coolingLoad.I.y,building.wall1.construction.layer[1].T[1],building.wall1.construction.layer[2].T[1],building.wall2.construction.layer[1].T[1],building.wall2.construction.layer[2].T[1],building.wall3.construction.layer[1].T[1],building.wall3.construction.layer[2].T[1],building.wall4.construction.layer[1].T[1],building.wall4.construction.layer[2].T[1],building.ceiling.construction.layer[1].T[1],building.ceiling.construction.layer[2].T[1],building.bottom.construction.layer[1].T[1],building.bottom.construction.layer[2].T[1],building.wallsInterior.construction.layer[1].T[1],building.wallsInterior.construction.layer[2].T[1],building.ceilingsInterior.construction.layer[1].T[1],building.ceilingsInterior.construction.layer[2].T[1],building.window1.heatTransfer.T,building.window2.heatTransfer.T,building.window3.heatTransfer.T,building.window4.heatTransfer.T) * Number of discrete variables: 2 ($whenCondition1,ambience.weatherDataReader.weatherData.conTim.tNext) * Number of discrete states: 1 (ambience.weatherDataReader.weatherData.conTim.tNext) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (490): * Single equations (assignments): 451 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 1 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 38 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 8 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 30 systems {(1,3), (15,55), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,3), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of Backend phase and start with SimCode phase: time 0.002925/2.642, allocations: 0.9066 MB / 1.559 GB, free: 220.2 MB / 0.8699 GB Notification: Performance of simCode: created initialization part: time 0.05715/2.699, allocations: 28.8 MB / 1.587 GB, free: 210.8 MB / 0.8699 GB Notification: Performance of simCode: created event and clocks part: time 9.307e-06/2.699, allocations: 2.969 kB / 1.587 GB, free: 210.8 MB / 0.8699 GB Notification: Performance of simCode: created simulation system equations: time 0.008672/2.707, allocations: 6.299 MB / 1.593 GB, free: 207.7 MB / 0.8699 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01119/2.719, allocations: 3.201 MB / 1.596 GB, free: 207.4 MB / 0.8699 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.05798/2.777, allocations: 35.62 MB / 1.631 GB, free: 179.3 MB / 0.8699 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.009516/2.786, allocations: 5.847 MB / 1.637 GB, free: 176.5 MB / 0.8699 GB Notification: Performance of simCode: alias equations: time 0.0131/2.799, allocations: 3.8 MB / 1.641 GB, free: 173 MB / 0.8699 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.008475/2.808, allocations: 2.566 MB / 1.643 GB, free: 171.1 MB / 0.8699 GB Notification: Performance of SimCode: time 1.783e-06/2.808, allocations: 0 / 1.643 GB, free: 171.1 MB / 0.8699 GB Notification: Performance of Templates: time 0.5773/3.385, allocations: 286.1 MB / 1.922 GB, free: 237.1 MB / 0.9012 GB " [Timeout remaining time 657] make -j1 -f BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox.makefile [Timeout 660] (rm -f BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox.pipe ; mkfifo BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox.pipe ; head -c 1048576 < BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox.pipe >> ../files/BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox.sim & ./BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox -abortSlowSimulation -alarm=240 -lv LOG_STATS > BuildingSystems_BuildingSystems.Buildings.Examples.BuildingThermal1Zone1DBox.pipe 2>&1) [Timeout 240] [Calling sys.exit(0), Time elapsed: 20.548612157348543]