Environment - simulationEnvironment: startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=480 stepSize=15 Regular simulation: ./AixLib_AixLib.Systems.ModularAHU.Examples.EONERC_AHU2 -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in EONERC_AHU2.genericAHU.fanSup: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in EONERC_AHU2.genericAHU.fanRet: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 75.000000 | | | | ((genericAHU.preheater.hydraulicModule.valve.actPos.y >= 0.0 and genericAHU.preheater.hydraulicModule.valve.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.preheater.hydraulicModule.valve.actPos.y <= 1.0, has value: -3.41608e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 135.000000 | | | | ((genericAHU.cooler.hydraulicModule.valve.res3.y >= 0.0 and genericAHU.cooler.hydraulicModule.valve.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.cooler.hydraulicModule.valve.res3.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 135.000000 | | | | ((genericAHU.cooler.hydraulicModule.valve.actPos.y >= 0.0 and genericAHU.cooler.hydraulicModule.valve.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.cooler.hydraulicModule.valve.actPos.y <= 1.0, has value: -6.41271e-15" LOG_STDOUT | error | simulation aborted (-alarm) LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.1921e-05s [ 0.0%] pre-initialization | | | | | | 0.0030423s [ 0.0%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 85.5978s [ 35.7%] solver (excl. callbacks) | | | | | | 0.000141637s [ 0.0%] creating output-file | | | | | | 8.20433s [ 3.4%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 146.195s [ 60.9%] simulation | | | | | | 240s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 328403 steps taken | | | | | | 700121 calls of functionODE | | | | | | 473767 evaluations of jacobian | | | | | | 574 error test failures | | | | | | 157338 convergence test failures | | | | | | 128.688s time of jacobian evaluation