Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./TransiEnt_TransiEnt.Grid.Heat.HeatGridControl.Check.TestHeatFlowDivision -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00115442s reading init.xml | | | | | | 9.3355e-05s reading info.xml | | | | | | 4.5235e-05s [ 2.8%] pre-initialization | | | | | | 6.8269e-05s [ 4.3%] initialization | | | | | | 4.81e-07s [ 0.0%] steps | | | | | | 2.2557e-05s [ 1.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.2618e-05s [ 0.8%] event-handling | | | | | | 0.000248314s [ 15.5%] overhead | | | | | | 0.00120759s [ 75.2%] simulation | | | | | | 0.00160507s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 2500 steps taken | | | | | | 2500 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.