Environment - simulationEnvironment: startTime=0 stopTime=25 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.025 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Examples.WaterHammer -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialVolume.mo:114:3-114:138:writable] | | | | The following assertion has been violated at time 7.425000 | | | | ((checkValve.inlet.m_flow > reservoir.m_flow_assert)) --> "In "WaterHammer.reservoir": Negative mass flow rate at Volume inlet" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00326206s reading init.xml | | | | | | 0.000257213s reading info.xml | | | | | | 0.000144652s [ 0.5%] pre-initialization | | | | | | 0.000351792s [ 1.3%] initialization | | | | | | 2.555e-06s [ 0.0%] steps | | | | | | 0.0054642s [ 20.2%] solver (excl. callbacks) | | | | | | 0.000265701s [ 1.0%] creating output-file | | | | | | 0.000968311s [ 3.6%] event-handling | | | | | | 0.00029346s [ 1.1%] overhead | | | | | | 0.0195786s [ 72.3%] simulation | | | | | | 0.0270693s [100.0%] total | | | | | events | | | | | | 53 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 9596 steps taken | | | | | | 17135 calls of functionODE | | | | | | 2116 evaluations of jacobian | | | | | | 653 error test failures | | | | | | 91 convergence test failures | | | | | | 0.00571401s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.