Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.4791/0.4791, allocations: 111.6 MB / 131.2 MB, free: 5.047 MB / 122.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin") translateModel(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.723e-06/1.723e-06, allocations: 0 / 176.2 MB, free: 9.191 MB / 170.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.697e-05/1.869e-05, allocations: 3.406 kB / 176.2 MB, free: 9.188 MB / 170.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin): time 1.015/1.015, allocations: 261.4 MB / 437.6 MB, free: 12 MB / 394.7 MB Notification: Performance of NFInst.instExpressions: time 0.3054/1.321, allocations: 148.3 MB / 0.5722 GB, free: 14.84 MB / 0.4948 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0004855/1.321, allocations: 12 kB / 0.5722 GB, free: 14.83 MB / 0.4948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/SourcePQ.mo:15:3-16:78:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/BoundaryConditions/Sink.mo:12:3-13:80:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:36:3-37:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:38:3-39:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:40:3-41:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeATh.mo:44:3-45:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:11:3-12:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:13:3-14:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:11:3-12:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:13:3-14:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:32:3-33:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:34:3-35:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:17:3-18:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:19:3-20:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:36:3-37:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:38:3-39:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:42:3-43:78:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeCTh.mo:44:3-45:80:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:11:3-12:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:13:3-14:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:11:3-12:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/SingularPressureLoss.mo:13:3-14:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:32:3-33:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Machines/StaticFan.mo:34:3-35:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:17:3-18:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/PressureLosses/CheckValve.mo:19:3-20:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:17:3-18:81:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:19:3-20:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Junctions/Mixer2.mo:21:3-22:79:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:36:3-37:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:38:3-39:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:40:3-41:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Volumes/VolumeDTh.mo:42:3-43:78:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/FlueGases/Sensors/TemperatureSensor.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0004706/1.322, allocations: 221.7 kB / 0.5724 GB, free: 14.61 MB / 0.4948 GB Notification: Performance of NFTyping.typeBindings: time 0.0007052/1.322, allocations: 0.5129 MB / 0.5729 GB, free: 14.09 MB / 0.4948 GB Notification: Performance of NFTyping.typeClassSections: time 0.002449/1.325, allocations: 1.537 MB / 0.5744 GB, free: 12.55 MB / 0.4948 GB Notification: Performance of NFFlatten.flatten: time 0.001762/1.327, allocations: 2.431 MB / 0.5768 GB, free: 10.12 MB / 0.4948 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001/1.328, allocations: 1.066 MB / 0.5778 GB, free: 9.008 MB / 0.4948 GB Notification: Performance of NFEvalConstants.evaluate: time 0.001013/1.329, allocations: 1.369 MB / 0.5792 GB, free: 7.637 MB / 0.4948 GB Notification: Performance of NFSimplifyModel.simplify: time 0.0006643/1.329, allocations: 0.7713 MB / 0.5799 GB, free: 6.863 MB / 0.4948 GB Notification: Performance of NFPackage.collectConstants: time 0.00023/1.329, allocations: 244 kB / 0.5802 GB, free: 6.625 MB / 0.4948 GB Notification: Performance of NFFlatten.collectFunctions: time 0.001401/1.331, allocations: 1.114 MB / 0.5812 GB, free: 5.508 MB / 0.4948 GB Notification: Performance of NFScalarize.scalarize: time 0.000253/1.331, allocations: 0.5101 MB / 0.5817 GB, free: 4.996 MB / 0.4948 GB Notification: Performance of NFVerifyModel.verify: time 0.0005176/1.332, allocations: 0.7406 MB / 0.5825 GB, free: 4.254 MB / 0.4948 GB Notification: Performance of NFConvertDAE.convert: time 0.001901/1.334, allocations: 2.192 MB / 0.5846 GB, free: 2.055 MB / 0.4948 GB Notification: Performance of FrontEnd - DAE generated: time 4.017e-06/1.334, allocations: 0 / 0.5846 GB, free: 2.055 MB / 0.4948 GB Notification: Performance of FrontEnd: time 1.403e-06/1.334, allocations: 0 / 0.5846 GB, free: 2.055 MB / 0.4948 GB Notification: Performance of Transformations before backend: time 4.058e-05/1.334, allocations: 4 kB / 0.5846 GB, free: 2.051 MB / 0.4948 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 508 * Number of variables: 508 Notification: Performance of Generate backend data structure: time 0.002435/1.336, allocations: 2.266 MB / 0.5868 GB, free: 15.73 MB / 0.5105 GB Notification: Performance of prepare preOptimizeDAE: time 3.794e-05/1.336, allocations: 15.98 kB / 0.5868 GB, free: 15.72 MB / 0.5105 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0003669/1.336, allocations: 387.7 kB / 0.5872 GB, free: 15.34 MB / 0.5105 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.0006755/1.337, allocations: 0.6789 MB / 0.5879 GB, free: 14.64 MB / 0.5105 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001234/1.337, allocations: 208.3 kB / 0.5881 GB, free: 14.42 MB / 0.5105 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0002691/1.337, allocations: 219.9 kB / 0.5883 GB, free: 14.21 MB / 0.5105 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.00205/1.34, allocations: 2.078 MB / 0.5903 GB, free: 11.88 MB / 0.5105 GB Notification: Performance of preOpt findStateOrder (simulation): time 3.018e-05/1.34, allocations: 11.88 kB / 0.5903 GB, free: 11.87 MB / 0.5105 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001023/1.34, allocations: 84 kB / 0.5904 GB, free: 11.79 MB / 0.5105 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 3.267e-05/1.34, allocations: 56.81 kB / 0.5904 GB, free: 11.73 MB / 0.5105 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.001512/1.341, allocations: 1.159 MB / 0.5916 GB, free: 10.57 MB / 0.5105 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.006168/1.347, allocations: 10.43 MB / 0.6018 GB, free: 15.84 MB / 0.5261 GB Notification: Performance of preOpt comSubExp (simulation): time 0.0008514/1.348, allocations: 0.7154 MB / 0.6025 GB, free: 15.1 MB / 0.5261 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.0005543/1.349, allocations: 477.1 kB / 0.6029 GB, free: 14.62 MB / 0.5261 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0003248/1.349, allocations: 196.8 kB / 0.6031 GB, free: 14.43 MB / 0.5261 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.0006684/1.35, allocations: 0.6305 MB / 0.6037 GB, free: 13.79 MB / 0.5261 GB Notification: Performance of pre-optimization done (n=128): time 3.156e-06/1.35, allocations: 0 / 0.6037 GB, free: 13.79 MB / 0.5261 GB Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default ======================================== 1: volume2S.T Please use -d=bltdump for more information. Notification: Performance of matching and sorting (n=213): time 0.06998/1.42, allocations: 24.04 MB / 0.6272 GB, free: 5.402 MB / 0.5417 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 2.7370521812699735]