Environment - simulationEnvironment: startTime=0 stopTime=10 tolerance=1e-08 numberOfIntervals=2500 stepSize=0.004 Regular simulation: ./OpenHydraulics_OpenHydraulics.DevelopmentTests.WallFrictionTest -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.000862561s reading init.xml | | | | | | 0.0040911s reading info.xml | | | | | | 6.4611e-05s [ 1.0%] pre-initialization | | | | | | 5.0595e-05s [ 0.8%] initialization | | | | | | 8.51e-07s [ 0.0%] steps | | | | | | 0.000598742s [ 9.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00325979s [ 49.1%] event-handling | | | | | | 0.0004011s [ 6.0%] overhead | | | | | | 0.00226582s [ 34.1%] simulation | | | | | | 0.00664152s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 508 steps taken | | | | | | 710 calls of functionODE | | | | | | 37 evaluations of jacobian | | | | | | 15 error test failures | | | | | | 0 convergence test failures | | | | | | 1.288e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.