Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step5Sink_free -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((massFlowRate.p_min >= 611.657 and massFlowRate.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= massFlowRate.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((superheater.p_min >= 611.657 and superheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= superheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((preheater.p_min >= 611.657 and preheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= preheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boiler.p_min >= 611.657 and boiler.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= boiler.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump.p_min >= 611.657 and pump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00443577s reading init.xml | | | | | | 0.000301997s reading info.xml | | | | | | 0.0028871s [ 19.5%] pre-initialization | | | | | | 0.000700487s [ 4.7%] initialization | | | | | | 9.8155e-05s [ 0.7%] steps | | | | | | 1.684e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000286172s [ 1.9%] creating output-file | | | | | | 0.000177405s [ 1.2%] event-handling | | | | | | 0.000251564s [ 1.7%] overhead | | | | | | 0.0103825s [ 70.2%] simulation | | | | | | 0.0147851s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 101 steps taken | | | | | | 101 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.