Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo): time 0.4871/0.4871, allocations: 111.6 MB / 131.2 MB, free: 4.09 MB / 122.7 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/package.mo) Running command: translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.503e-06/1.503e-06, allocations: 0 / 176.2 MB, free: 9.113 MB / 170.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 1.485e-05/1.635e-05, allocations: 2.312 kB / 176.2 MB, free: 9.109 MB / 170.7 MB Notification: Automatically loaded package Complex 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.1.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.1.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC): time 1.291/1.291, allocations: 361.3 MB / 0.525 GB, free: 15.41 MB / 458.7 MB Notification: Performance of NFInst.instExpressions: time 0.4564/1.747, allocations: 243.2 MB / 0.7624 GB, free: 13.68 MB / 0.6198 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01943/1.766, allocations: 0.5783 MB / 0.763 GB, free: 13.68 MB / 0.6198 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:98:3-99:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:100:3-101:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:102:3-103:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:104:3-105:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:115:3-116:133:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:117:3-118:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:119:3-120:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:98:3-99:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:100:3-101:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:102:3-103:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:104:3-105:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:115:3-116:133:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:117:3-118:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:119:3-120:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:77:3-78:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:81:3-82:131:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeB.mo:83:3-84:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:98:3-99:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:100:3-101:80:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:102:3-103:82:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:104:3-105:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:115:3-116:133:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:117:3-118:81:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/DynamicDrum.mo:119:3-120:79:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SinkP.mo:32:3-33:80:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:73:3-74:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:77:3-78:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:136:3-137:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:140:3-141:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:53:3-54:77:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:55:3-56:79:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:57:3-58:80:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:59:3-60:78:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:46:3-47:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:48:3-49:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:52:3-53:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:46:3-47:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:48:3-49:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:52:3-53:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:46:3-47:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:48:3-49:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StodolaTurbine.mo:52:3-53:99:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:90:3-91:78:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:92:3-93:79:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:98:3-99:81:writable] Warning: Connector Cee is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:100:3-101:79:writable] Warning: Connector Cse is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceQ.mo:39:3-40:78:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SinkP.mo:32:3-33:80:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:77:3-78:80:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:81:3-82:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeA.mo:83:3-84:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:40:3-41:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:42:3-43:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:40:3-41:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:42:3-43:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:33:3-34:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Junctions/MassFlowMultiplier.mo:35:3-36:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:40:3-41:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/StaticCentrifugalPump.mo:42:3-43:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:6:3-7:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Sensors/SensorQ.mo:8:3-9:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:26:3-27:80:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/PipePressureLoss.mo:28:3-29:78:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:77:3-78:80:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:79:3-80:78:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:81:3-82:80:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeD.mo:83:3-84:64:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:77:3-78:135:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:79:3-80:131:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:81:3-82:78:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Volumes/VolumeC.mo:83:3-84:121:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:29:3-30:81:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/PressureLosses/ControlValve.mo:31:3-32:79:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/BoundaryConditions/SourceQ.mo:39:3-40:78:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0159/1.782, allocations: 6.103 MB / 0.769 GB, free: 12.97 MB / 0.6198 GB Notification: Performance of NFTyping.typeBindings: time 0.0396/1.822, allocations: 18.92 MB / 0.7874 GB, free: 4.168 MB / 0.6198 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:470:9-470:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:525:9-525:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:708:9-708:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph.mo:51:3-51:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ph_der.mo:118:3-118:151:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/Fluid/derDensity_derP_derh.mo:56:5-56:88:writable] Warning: T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteam/IF97_packages.mo:964:9-964:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Properties/WaterSteamSimple/prop4_Ps.mo:51:3-51:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.06699/1.889, allocations: 36.56 MB / 0.8231 GB, free: 12.31 MB / 0.6511 GB Notification: Performance of NFFlatten.flatten: time 0.08876/1.978, allocations: 112.8 MB / 0.9333 GB, free: 13.61 MB / 0.7448 GB Notification: Performance of NFFlatten.resolveConnections: time 0.04207/2.02, allocations: 35.29 MB / 0.9678 GB, free: 11.97 MB / 0.7761 GB Notification: Performance of NFEvalConstants.evaluate: time 0.5942/2.614, allocations: 52.86 MB / 1.019 GB, free: 34.5 MB / 0.7762 GB Notification: Performance of NFSimplifyModel.simplify: time 0.05317/2.667, allocations: 36.77 MB / 1.055 GB, free: 34.5 MB / 0.7762 GB Notification: Performance of NFPackage.collectConstants: time 0.0271/2.694, allocations: 8.362 MB / 1.063 GB, free: 34.5 MB / 0.7762 GB Notification: Performance of NFFlatten.collectFunctions: time 0.07082/2.765, allocations: 36.7 MB / 1.099 GB, free: 33.83 MB / 0.7762 GB Notification: Performance of NFScalarize.scalarize: time 0.03379/2.799, allocations: 25.75 MB / 1.124 GB, free: 26.91 MB / 0.7762 GB Notification: Performance of NFVerifyModel.verify: time 0.0484/2.847, allocations: 25.8 MB / 1.15 GB, free: 13.02 MB / 0.7762 GB Notification: Performance of NFConvertDAE.convert: time 0.1225/2.97, allocations: 82.43 MB / 1.23 GB, free: 5.922 MB / 0.8387 GB Notification: Performance of FrontEnd - DAE generated: time 6.543e-06/2.97, allocations: 0 / 1.23 GB, free: 5.922 MB / 0.8387 GB Notification: Performance of FrontEnd: time 1.483e-06/2.97, allocations: 0 / 1.23 GB, free: 5.922 MB / 0.8387 GB Notification: Performance of Transformations before backend: time 0.002339/2.972, allocations: 0 / 1.23 GB, free: 5.922 MB / 0.8387 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 15109 * Number of variables: 15109 Notification: Performance of Generate backend data structure: time 0.5985/3.571, allocations: 105.5 MB / 1.333 GB, free: 247.6 MB / 0.9169 GB Notification: Performance of prepare preOptimizeDAE: time 4.279e-05/3.571, allocations: 12.39 kB / 1.333 GB, free: 247.6 MB / 0.9169 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.03686/3.607, allocations: 12.14 MB / 1.345 GB, free: 244.4 MB / 0.9169 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.03869/3.646, allocations: 23.37 MB / 1.368 GB, free: 242.4 MB / 0.9169 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.01288/3.659, allocations: 25.1 MB / 1.392 GB, free: 219.5 MB / 0.9169 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.01325/3.672, allocations: 4.722 MB / 1.397 GB, free: 219.4 MB / 0.9169 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.1179/3.79, allocations: 61.99 MB / 1.458 GB, free: 191.6 MB / 0.9169 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001128/3.791, allocations: 187.2 kB / 1.458 GB, free: 191.6 MB / 0.9169 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.01042/3.802, allocations: 1.962 MB / 1.46 GB, free: 190.1 MB / 0.9169 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0008973/3.803, allocations: 1.701 MB / 1.461 GB, free: 189.8 MB / 0.9169 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.09056/3.893, allocations: 35.91 MB / 1.496 GB, free: 165.2 MB / 0.9169 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.8033/4.696, allocations: 309.7 MB / 1.799 GB, free: 59.55 MB / 0.9484 GB Notification: Performance of preOpt comSubExp (simulation): time 0.06817/4.765, allocations: 43.92 MB / 1.842 GB, free: 49.15 MB / 0.9484 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.04113/4.806, allocations: 16.89 MB / 1.858 GB, free: 48.7 MB / 0.9484 GB Notification: Performance of preOpt evalFunc (simulation): time 0.9269/5.733, allocations: 410.2 MB / 2.259 GB, free: 131 MB / 0.9796 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.06014/5.793, allocations: 30 MB / 2.288 GB, free: 106 MB / 0.9796 GB Notification: Performance of pre-optimization done (n=7660): time 6.297e-05/5.793, allocations: 0 / 2.288 GB, free: 106 MB / 0.9796 GB Notification: Performance of matching and sorting (n=7668): time 0.7943/6.587, allocations: 214.6 MB / 2.498 GB, free: 194.1 MB / 0.9796 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0003669/6.588, allocations: 1.537 MB / 2.499 GB, free: 192.3 MB / 0.9796 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.01898/6.607, allocations: 17.23 MB / 2.516 GB, free: 182.9 MB / 0.9796 GB Notification: Performance of collectPreVariables (initialization): time 0.01062/6.617, allocations: 0.7763 MB / 2.517 GB, free: 182.7 MB / 0.9796 GB Notification: Performance of collectInitialEqns (initialization): time 0.008961/6.626, allocations: 16.98 MB / 2.533 GB, free: 173.9 MB / 0.9796 GB Notification: Performance of collectInitialBindings (initialization): time 0.02503/6.651, allocations: 29.28 MB / 2.562 GB, free: 152.2 MB / 0.9796 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.03662/6.688, allocations: 13.73 MB / 2.575 GB, free: 140.5 MB / 0.9796 GB Notification: Performance of setup shared object (initialization): time 3.998e-05/6.688, allocations: 480.8 kB / 2.576 GB, free: 140.1 MB / 0.9796 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.04067/6.728, allocations: 15.21 MB / 2.591 GB, free: 125.8 MB / 0.9796 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.3388/7.067, allocations: 37.97 MB / 2.628 GB, free: 222.5 MB / 0.9796 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.1576/7.225, allocations: 94.06 MB / 2.72 GB, free: 194.7 MB / 0.9796 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0007172/7.226, allocations: 117.9 kB / 2.72 GB, free: 194.7 MB / 0.9796 GB Notification: Performance of matching and sorting (n=10045) (initialization): time 0.2296/7.455, allocations: 77.11 MB / 2.795 GB, free: 178 MB / 0.9796 GB Notification: Performance of prepare postOptimizeDAE: time 0.0003293/7.456, allocations: 236.8 kB / 2.795 GB, free: 177.8 MB / 0.9796 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0008678/7.456, allocations: 486.2 kB / 2.796 GB, free: 177.3 MB / 0.9796 GB Notification: Performance of postOpt tearingSystem (initialization): time 4.541/12, allocations: 2.33 GB / 5.126 GB, free: 227 MB / 1.027 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.02124/12.02, allocations: 7.872 MB / 5.134 GB, free: 223.9 MB / 1.027 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.2148/12.23, allocations: 80.53 MB / 5.212 GB, free: 164.7 MB / 1.027 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.04373/12.28, allocations: 4.823 MB / 5.217 GB, free: 161.9 MB / 1.027 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01486/12.29, allocations: 2.984 MB / 5.22 GB, free: 159.9 MB / 1.027 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.EconomiseurHP4.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP1.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.SurchauffeurHP2.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.SurchauffeurMP2.TwoPhaseFlowPipe.Q[4] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1909 * Number of states: 0 () * Number of discrete variables: 400 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,VolumeAlimMPHP.Cs1.diff_on_2,EconomiseurMP.Cws1.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_2,Vanne_alimentationMPHP1.C2.diff_on_1,perteChargeK.C2.diff_on_2,CapteurDebitEauCondenseur.C1.diff_on_2,perteChargeK2.C2.diff_on_1,vanne_extraction.C2.diff_on_1,SourceFumees.C.ftype,DoubleDebitMP.Cs.ftype,MelangeurPreTMP.Cs.ftype,MelangeurPreTMP.Ce3.ftype,MelangeurPreTMP.Ce2.ftype,MelangeurPreTMP.fluids[1],VolumePreTHP.Cs3.ftype,VolumePreTHP.Cs2.ftype,VolumePreTHP.Cs1.ftype,DoubleDebitHP.Cs.ftype,VolumePreTHP.fluids[1],VolumeAlimMPHP.Cs1.ftype,VolumeAlimMPHP.Cs2.ftype,VolumeECO_HP2_3.Cs.ftype,VolumeECO_HP2_3.Ce3.ftype,VolumeECO_HP2_3.Ce2.ftype,VolumeECO_HP1_2.Cs.ftype,VolumeECO_HP2_3.fluids[1],VolumeECO_HP1_2.Ce3.ftype,VolumeECO_HP1_2.Ce2.ftype,VolumeECO_HP1_2.fluids[1],regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,MelangeurHPMP.Cs2.ftype,MelangeurPostTMP1.Cs.ftype,Condenseur.Cl.ftype,BallonBP.Cs.ftype,VolumeCond1.Cs.ftype,BallonBP.Cv.ftype,BallonMP.Cv.ftype,BallonHP.Cv.ftype,DoubleDebitBP.Cs.ftype,DoubleDebitBP.fluids[1],MoitieDebitBP.Cs.ftype,MoitieDebitBP.fluids[1],VolumeAlimMPHP.Ce2.ftype,VolumeAlimMPHP.fluids[1],VolumeCond1.Ce2.ftype,VolumeCond1.Ce1.ftype,VolumeCond1.fluids[1],SourceCaloporteur.C.ftype,MoitieDebitHP.Cs.ftype,MoitieDebitHP.fluids[1],DoubleDebitMP.fluids[1],DoubleDebitHP.fluids[1],MelangeurPostTMP1.Ce3.ftype,MelangeurPostTMP1.fluids[1],VolumeEvapBP.Cs.ftype,VolumeEvapBP.Ce3.ftype,VolumeEvapBP.Ce2.ftype,BallonBP.Cd.ftype,VolumeEvapBP.fluids[1],BallonBP.Ce3.ftype,BallonBP.Ce2.ftype,BallonBP.fluids[1],MelangeurHPMP.Cs1.ftype,MelangeurHPMP.fluids[1],VolumeEvapMP.Cs.ftype,VolumeEvapMP.Ce3.ftype,VolumeEvapMP.Ce2.ftype,BallonMP.Cd.ftype,VolumeEvapMP.fluids[1],BallonMP.Cs.ftype,BallonMP.Ce3.ftype,BallonMP.Ce2.ftype,BallonMP.fluids[1],VolumeEvapHP.Cs.ftype,VolumeEvapHP.Ce3.ftype,VolumeEvapHP.Ce2.ftype,BallonHP.Cd.ftype,VolumeEvapHP.fluids[1],BallonHP.Cs.ftype,BallonHP.Ce3.ftype,BallonHP.Ce2.ftype,BallonHP.fluids[1],vanne_alimentationHP.fluid,vanne_vapeurHP.fluid,GainChargeHP.fluid,EvaporateurHP.ExchangerFlueGasesMetal.fluid,EvaporateurHP.TwoPhaseFlowPipe.fluid,EconomiseurHP4.ExchangerFlueGasesMetal.fluid,EconomiseurHP4.TwoPhaseFlowPipe.fluid,SurchauffeurHP1.ExchangerFlueGasesMetal.fluid,SurchauffeurHP1.TwoPhaseFlowPipe.fluid,EconomiseurHP3.ExchangerFlueGasesMetal.fluid,EconomiseurHP3.TwoPhaseFlowPipe.fluid,EconomiseurHP2.ExchangerFlueGasesMetal.fluid,EconomiseurHP2.TwoPhaseFlowPipe.fluid,EconomiseurHP1.ExchangerFlueGasesMetal.fluid,EconomiseurHP1.TwoPhaseFlowPipe.fluid,SurchauffeurHP2.ExchangerFlueGasesMetal.fluid,SurchauffeurHP2.TwoPhaseFlowPipe.fluid,SurchauffeurHP3.ExchangerFlueGasesMetal.fluid,SurchauffeurHP3.TwoPhaseFlowPipe.fluid,vanne_alimentationMP.fluid,vanne_vapeurMP.fluid,EvaporateurMP.ExchangerFlueGasesMetal.fluid,EvaporateurMP.TwoPhaseFlowPipe.fluid,GainChargeMP.fluid,EconomiseurMP.ExchangerFlueGasesMetal.fluid,EconomiseurMP.TwoPhaseFlowPipe.fluid,SurchauffeurMP1.ExchangerFlueGasesMetal.fluid,SurchauffeurMP1.TwoPhaseFlowPipe.fluid,SurchauffeurMP2.ExchangerFlueGasesMetal.fluid,SurchauffeurMP2.TwoPhaseFlowPipe.fluid,SurchauffeurMP3.ExchangerFlueGasesMetal.fluid,SurchauffeurMP3.TwoPhaseFlowPipe.fluid,vanne_vapeurBP.fluid,vanne_alimentationBP.fluid,GainChargeBP.fluid,EvaporateurBP.ExchangerFlueGasesMetal.fluid,EvaporateurBP.TwoPhaseFlowPipe.fluid,Vanne_alimentationMPHP.fluid,SurchauffeurBP.ExchangerFlueGasesMetal.fluid,SurchauffeurBP.TwoPhaseFlowPipe.fluid,PuitsFumees.fluid,EconomiseurBP.ExchangerFlueGasesMetal.fluid,EconomiseurBP.TwoPhaseFlowPipe.fluid,TurbineHP.fluid,TurbineMP.fluid,TurbineBP.fluid,Condenseur.fluid_p,PuitsCaloporteur.fluid,perteChargeK1.fluid,perteChargeKCond1.fluid,PompeAlimMP.fluid,PompeAlimHP.fluid,PerteChargeZero2.fluid,perteChargeK3.fluid,perteChargeK8.fluid,perteChargeK.fluid,PompeAlimBP.fluid,perteChargeK2.fluid,vanne_extraction.fluid,lumpedStraightPipeK2.fluid,vanne_entree_TurbineHP.fluid,Vanne_alimentationMPHP1.fluid,Vanne_alimentationMPHP2.fluid,vanne_entree_TurbineMP.fluid,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal,$whenCondition1,SourceFumees.fluid1,MelangeurPreTMP.fluid1,VolumePreTHP.fluid1,VolumeECO_HP2_3.fluid1,VolumeECO_HP1_2.fluid1,DoubleDebitBP.fluid1,MoitieDebitBP.fluid1,VolumeAlimMPHP.fluid1,VolumeCond1.fluid1,SourceCaloporteur.fluid1,MoitieDebitHP.fluid1,DoubleDebitMP.fluid1,DoubleDebitHP.fluid1,MelangeurPostTMP1.fluid1,VolumeEvapBP.fluid1,MelangeurHPMP.fluid1,VolumeEvapMP.fluid1,VolumeEvapHP.fluid1,MelangeurPreTMP.Ce1.diff_on_2,DoubleDebitMP.Cs.diff_on_2,DoubleDebitMP.Cs.diff_on_1,vanne_entree_TurbineMP.C2.diff_on_1,MelangeurPreTMP.Cs.diff_on_1,TurbineMP.Cs.diff_on_1,MelangeurPreTMP.Ce3.diff_on_2,MelangeurPreTMP.Ce2.diff_on_2,MelangeurPreTMP.Ce3.diff_on_1,MelangeurPreTMP.Ce2.diff_on_1,VolumePreTHP.Cs3.diff_on_1,TurbineHP.Cs.diff_on_1,VolumePreTHP.Cs2.diff_on_1,VolumePreTHP.Cs1.diff_on_1,VolumePreTHP.Ce.diff_on_2,DoubleDebitHP.Cs.diff_on_2,VolumePreTHP.Cs2.diff_on_2,VolumePreTHP.Cs1.diff_on_2,EconomiseurMP.TwoPhaseFlowPipe.C1.diff_on_2,PompeAlimMP.C2.diff_on_2,perteChargeK8.C2.diff_on_2,VolumeAlimMPHP.Cs1.diff_on_1,perteChargeK8.C2.diff_on_1,PompeAlimMP.C2.diff_on_1,EconomiseurHP1.TwoPhaseFlowPipe.C1.diff_on_2,Vanne_alimentationMPHP1.C1.diff_on_2,perteChargeK3.C2.diff_on_2,VolumeAlimMPHP.Cs2.diff_on_1,perteChargeK3.C2.diff_on_1,Vanne_alimentationMPHP1.C1.diff_on_1,VolumeECO_HP2_3.Cs.diff_on_1,VolumeECO_HP2_3.Ce3.diff_on_2,VolumeECO_HP2_3.Ce2.diff_on_2,VolumeECO_HP2_3.Ce1.diff_on_2,VolumeECO_HP2_3.Ce3.diff_on_1,VolumeECO_HP2_3.Ce2.diff_on_1,VolumeECO_HP1_2.Cs.diff_on_1,VolumeECO_HP1_2.Ce3.diff_on_2,VolumeECO_HP1_2.Ce2.diff_on_2,VolumeECO_HP1_2.Ce1.diff_on_2,VolumeECO_HP1_2.Ce3.diff_on_1,VolumeECO_HP1_2.Ce2.diff_on_1,DoubleDebitHP.Cs.diff_on_1,vanne_entree_TurbineHP.C2.diff_on_1,SurchauffeurMP2.TwoPhaseFlowPipe.C1.diff_on_2,lumpedStraightPipeK2.C1.diff_on_2,MelangeurHPMP.Cs2.diff_on_1,SurchauffeurMP2.Cws1.diff_on_1,Condenseur.Cv.diff_on_2,TurbineBP.Cs.diff_on_2,MelangeurPostTMP1.Cs.diff_on_2,MelangeurPostTMP1.Cs.diff_on_1,TurbineBP.Cs.diff_on_1,CapteurDebitVapCondenseur.C2.diff_on_1,MoitieDebitBP.Ce.diff_on_2,vanne_extraction.C2.diff_on_2,PompeAlimBP.C2.diff_on_2,Condenseur.Cl.diff_on_1,perteChargeK.C2.diff_on_1,PompeAlimBP.C2.diff_on_1,VolumeAlimMPHP.Ce1.diff_on_2,CapteurDebitEauBPsortie.C1.diff_on_2,BallonBP.Cs.diff_on_1,Vanne_alimentationMPHP.C2.diff_on_1,BallonBP.Ce1.diff_on_2,CapteurDebitEauBP.C1.diff_on_2,EconomiseurBP.TwoPhaseFlowPipe.C2.diff_on_1,BallonBP.Ce1.diff_on_1,SurchauffeurBP.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurBP.C1.diff_on_2,BallonBP.Cv.diff_on_1,CapteurDebitVapBP.C2.diff_on_1,SurchauffeurMP1.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurMP.C1.diff_on_2,BallonMP.Cv.diff_on_1,CapteurDebitVapMP.C2.diff_on_1,BallonMP.Ce1.diff_on_2,CapteurDebitEauMP.C1.diff_on_2,EconomiseurMP.TwoPhaseFlowPipe.C2.diff_on_1,BallonMP.Ce1.diff_on_1,BallonHP.Ce1.diff_on_2,CapteurDebitEauHP.C1.diff_on_2,EconomiseurHP4.TwoPhaseFlowPipe.C2.diff_on_1,BallonHP.Ce1.diff_on_1,SurchauffeurHP1.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurHP.C1.diff_on_2,BallonHP.Cv.diff_on_1,CapteurDebitVapHP.C2.diff_on_1,MelangeurPostTMP1.Ce2.diff_on_2,DoubleDebitBP.Cs.diff_on_2,DoubleDebitBP.Cs.diff_on_1,MelangeurPostTMP1.Ce2.diff_on_1,DoubleDebitBP.Ce.diff_on_2,MoitieDebitBP.Cs.diff_on_1,VolumeAlimMPHP.Ce2.diff_on_2,VolumeAlimMPHP.Ce2.diff_on_1,EconomiseurBP.TwoPhaseFlowPipe.C1.diff_on_2,VolumeCond1.Cs.diff_on_2,VolumeCond1.Cs.diff_on_1,EconomiseurBP.Cws1.diff_on_1,VolumeCond1.Ce3.diff_on_2,VolumeCond1.Ce2.diff_on_2,VolumeCond1.Ce1.diff_on_2,VolumeCond1.Ce2.diff_on_1,VolumeCond1.Ce1.diff_on_1,MoitieDebitHP.Cs.diff_on_1,MoitieDebitHP.Ce.diff_on_2,VolumePreTHP.Cs3.diff_on_2,DoubleDebitMP.Ce.diff_on_2,DoubleDebitHP.Ce.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_2,MelangeurPostTMP1.Ce1.diff_on_2,MelangeurPreTMP.Cs.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_1,EconomiseurBP.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurBP.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurBP.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurBP.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurBP.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurBP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurBP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurBP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurBP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapBP.Cs.diff_on_1,VolumeEvapBP.Ce3.diff_on_2,VolumeEvapBP.Ce2.diff_on_2,VolumeEvapBP.Ce1.diff_on_2,BallonBP.Cd.diff_on_2,VolumeEvapBP.Ce3.diff_on_1,VolumeEvapBP.Ce2.diff_on_1,BallonBP.Cd.diff_on_1,VolumeEvapBP.Ce1.diff_on_1,BallonBP.Cm.diff_on_2,BallonBP.Ce3.diff_on_2,BallonBP.Ce2.diff_on_2,BallonBP.Ce3.diff_on_1,BallonBP.Ce2.diff_on_1,SurchauffeurMP3.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurMP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP3.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurMP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP2.ExchangerFlueGasesMetal.C2.diff_on_1,MelangeurHPMP.Cs1.diff_on_1,MelangeurHPMP.Ce2.diff_on_2,MelangeurHPMP.Ce1.diff_on_2,MelangeurHPMP.Cs1.diff_on_2,SurchauffeurMP1.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurMP.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurMP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapMP.Cs.diff_on_1,VolumeEvapMP.Ce3.diff_on_2,VolumeEvapMP.Ce2.diff_on_2,VolumeEvapMP.Ce1.diff_on_2,GainChargeMP.C1.diff_on_2,VolumeEvapMP.Ce3.diff_on_1,VolumeEvapMP.Ce2.diff_on_1,BallonMP.Cd.diff_on_1,VolumeEvapMP.Ce1.diff_on_1,EvaporateurMP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurMP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurMP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurMP.ExchangerFlueGasesMetal.C2.diff_on_1,BallonMP.Cs.diff_on_1,BallonMP.Cm.diff_on_2,BallonMP.Ce3.diff_on_2,BallonMP.Ce2.diff_on_2,BallonMP.Cs.diff_on_2,BallonMP.Ce3.diff_on_1,BallonMP.Ce2.diff_on_1,SurchauffeurHP3.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP2.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP1.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP2.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP2.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP3.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP3.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP1.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP4.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP4.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP4.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurHP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurHP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurHP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurHP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapHP.Cs.diff_on_1,VolumeEvapHP.Ce3.diff_on_2,VolumeEvapHP.Ce2.diff_on_2,VolumeEvapHP.Ce1.diff_on_2,GainChargeHP.C1.diff_on_2,VolumeEvapHP.Ce3.diff_on_1,VolumeEvapHP.Ce2.diff_on_1,BallonHP.Cd.diff_on_1,VolumeEvapHP.Ce1.diff_on_1,BallonHP.Cs.diff_on_1,BallonHP.Cm.diff_on_2,BallonHP.Ce3.diff_on_2,BallonHP.Ce2.diff_on_2,BallonHP.Cs.diff_on_2,BallonHP.Ce3.diff_on_1,BallonHP.Ce2.diff_on_1) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (3646): * Single equations (assignments): 3593 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 34 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 12 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 5 systems {1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(4,1,62.5%)} * Non-linear torn systems (#iteration vars, #inner vars): 11 systems {(1,1), (1,15), (1,5), (2,11), (1,1), (1,15), (305,2988), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.03193/12.32, allocations: 3.43 MB / 5.223 GB, free: 158.8 MB / 1.027 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.02884/12.35, allocations: 5.449 MB / 5.228 GB, free: 156.2 MB / 1.027 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.226/12.58, allocations: 82.47 MB / 5.309 GB, free: 101 MB / 1.027 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.4978/13.08, allocations: 65.33 MB / 5.373 GB, free: 252.8 MB / 1.027 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0001997/13.08, allocations: 23.38 kB / 5.373 GB, free: 252.8 MB / 1.027 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001141/13.08, allocations: 300.3 kB / 5.373 GB, free: 252.8 MB / 1.027 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.3669/13.44, allocations: 150.2 MB / 5.52 GB, free: 231.4 MB / 1.027 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.001174/13.45, allocations: 89.94 kB / 5.52 GB, free: 231.4 MB / 1.027 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.03528/13.48, allocations: 11.34 MB / 5.531 GB, free: 229.2 MB / 1.027 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.09112/13.57, allocations: 39.61 MB / 5.57 GB, free: 190.4 MB / 1.027 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.01511/13.59, allocations: 2.056 MB / 5.572 GB, free: 188.3 MB / 1.027 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.4473/14.03, allocations: 249.9 MB / 5.816 GB, free: 163.8 MB / 1.027 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.231e-05/14.03, allocations: 37.94 kB / 5.816 GB, free: 163.8 MB / 1.027 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.3008/14.34, allocations: 101.2 MB / 5.915 GB, free: 151.4 MB / 1.027 GB Notification: Performance of postOpt removeConstants (simulation): time 0.03672/14.37, allocations: 13.1 MB / 5.927 GB, free: 150.9 MB / 1.027 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.01884/14.39, allocations: 1.233 MB / 5.929 GB, free: 150.9 MB / 1.027 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.03739/14.43, allocations: 4.248 MB / 5.933 GB, free: 150.9 MB / 1.027 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.02211/14.45, allocations: 4.885 MB / 5.938 GB, free: 150.8 MB / 1.027 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.01588/14.47, allocations: 2.242 MB / 5.94 GB, free: 150.8 MB / 1.027 GB Notification: Performance of sorting global known variables: time 0.01537/14.48, allocations: 9.287 MB / 5.949 GB, free: 149.9 MB / 1.027 GB Notification: Performance of sort global known variables: time 2.31e-07/14.48, allocations: 0 / 5.949 GB, free: 149.9 MB / 1.027 GB Notification: Performance of remove unused functions: time 0.06984/14.55, allocations: 19 MB / 5.967 GB, free: 139.1 MB / 1.027 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 105 * Number of states: 249 (MelangeurPreTMP.h,MelangeurPreTMP.P,VolumePreTHP.h,VolumePreTHP.P,VolumeECO_HP2_3.h,VolumeECO_HP2_3.P,VolumeECO_HP1_2.h,VolumeECO_HP1_2.P,regulation_Niveau_Condenseur.pT1_3.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_HP.pIsat.Integrateur1.x,VolumeAlimMPHP.h,VolumeCond1.h,Condenseur.Vl,Condenseur.hv,Condenseur.hl,Condenseur.P,MelangeurPostTMP1.h,EconomiseurBP.TwoPhaseFlowPipe.h[4],EconomiseurBP.TwoPhaseFlowPipe.h[3],EconomiseurBP.TwoPhaseFlowPipe.h[2],EconomiseurBP.TwoPhaseFlowPipe.Q[4],EconomiseurBP.TwoPhaseFlowPipe.Q[3],EconomiseurBP.TwoPhaseFlowPipe.Q[2],EconomiseurBP.TwoPhaseFlowPipe.Q[1],EconomiseurBP.TwoPhaseFlowPipe.P[4],EconomiseurBP.TwoPhaseFlowPipe.P[3],EconomiseurBP.TwoPhaseFlowPipe.P[2],EconomiseurBP.ExchangerWall.Tp[3],EconomiseurBP.ExchangerWall.Tp[2],EconomiseurBP.ExchangerWall.Tp[1],SurchauffeurBP.TwoPhaseFlowPipe.h[4],SurchauffeurBP.TwoPhaseFlowPipe.h[3],SurchauffeurBP.TwoPhaseFlowPipe.h[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[4],SurchauffeurBP.TwoPhaseFlowPipe.Q[3],SurchauffeurBP.TwoPhaseFlowPipe.Q[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[1],SurchauffeurBP.TwoPhaseFlowPipe.P[4],SurchauffeurBP.TwoPhaseFlowPipe.P[3],SurchauffeurBP.TwoPhaseFlowPipe.P[2],SurchauffeurBP.ExchangerWall.Tp[3],SurchauffeurBP.ExchangerWall.Tp[2],SurchauffeurBP.ExchangerWall.Tp[1],EvaporateurBP.TwoPhaseFlowPipe.h[4],EvaporateurBP.TwoPhaseFlowPipe.h[3],EvaporateurBP.TwoPhaseFlowPipe.h[2],EvaporateurBP.TwoPhaseFlowPipe.Q[4],EvaporateurBP.TwoPhaseFlowPipe.Q[3],EvaporateurBP.TwoPhaseFlowPipe.Q[2],EvaporateurBP.TwoPhaseFlowPipe.Q[1],EvaporateurBP.TwoPhaseFlowPipe.P[4],EvaporateurBP.TwoPhaseFlowPipe.P[3],EvaporateurBP.TwoPhaseFlowPipe.P[2],EvaporateurBP.ExchangerWall.Tp[3],EvaporateurBP.ExchangerWall.Tp[2],EvaporateurBP.ExchangerWall.Tp[1],VolumeEvapBP.h,BallonBP.Vl,BallonBP.Tp,BallonBP.hv,BallonBP.hl,BallonBP.P,SurchauffeurMP3.TwoPhaseFlowPipe.h[4],SurchauffeurMP3.TwoPhaseFlowPipe.h[3],SurchauffeurMP3.TwoPhaseFlowPipe.h[2],SurchauffeurMP3.TwoPhaseFlowPipe.Q[4],SurchauffeurMP3.TwoPhaseFlowPipe.Q[3],SurchauffeurMP3.TwoPhaseFlowPipe.Q[2],SurchauffeurMP3.TwoPhaseFlowPipe.P[4],SurchauffeurMP3.TwoPhaseFlowPipe.P[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[2],SurchauffeurMP3.ExchangerWall.Tp[3],SurchauffeurMP3.ExchangerWall.Tp[2],SurchauffeurMP3.ExchangerWall.Tp[1],SurchauffeurMP2.TwoPhaseFlowPipe.h[4],SurchauffeurMP2.TwoPhaseFlowPipe.h[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[4],SurchauffeurMP2.TwoPhaseFlowPipe.Q[3],SurchauffeurMP2.TwoPhaseFlowPipe.Q[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[1],SurchauffeurMP2.TwoPhaseFlowPipe.P[4],SurchauffeurMP2.TwoPhaseFlowPipe.P[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[2],SurchauffeurMP2.ExchangerWall.Tp[3],SurchauffeurMP2.ExchangerWall.Tp[2],SurchauffeurMP2.ExchangerWall.Tp[1],MelangeurHPMP.h,SurchauffeurMP1.TwoPhaseFlowPipe.h[4],SurchauffeurMP1.TwoPhaseFlowPipe.h[3],SurchauffeurMP1.TwoPhaseFlowPipe.h[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[4],SurchauffeurMP1.TwoPhaseFlowPipe.Q[3],SurchauffeurMP1.TwoPhaseFlowPipe.Q[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[1],SurchauffeurMP1.TwoPhaseFlowPipe.P[4],SurchauffeurMP1.TwoPhaseFlowPipe.P[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[2],SurchauffeurMP1.ExchangerWall.Tp[3],SurchauffeurMP1.ExchangerWall.Tp[2],SurchauffeurMP1.ExchangerWall.Tp[1],EconomiseurMP.TwoPhaseFlowPipe.h[4],EconomiseurMP.TwoPhaseFlowPipe.h[3],EconomiseurMP.TwoPhaseFlowPipe.h[2],EconomiseurMP.TwoPhaseFlowPipe.Q[4],EconomiseurMP.TwoPhaseFlowPipe.Q[3],EconomiseurMP.TwoPhaseFlowPipe.Q[2],EconomiseurMP.TwoPhaseFlowPipe.Q[1],EconomiseurMP.TwoPhaseFlowPipe.P[4],EconomiseurMP.TwoPhaseFlowPipe.P[3],EconomiseurMP.TwoPhaseFlowPipe.P[2],EconomiseurMP.ExchangerWall.Tp[3],EconomiseurMP.ExchangerWall.Tp[2],EconomiseurMP.ExchangerWall.Tp[1],VolumeEvapMP.h,EvaporateurMP.TwoPhaseFlowPipe.h[4],EvaporateurMP.TwoPhaseFlowPipe.h[3],EvaporateurMP.TwoPhaseFlowPipe.h[2],EvaporateurMP.TwoPhaseFlowPipe.Q[4],EvaporateurMP.TwoPhaseFlowPipe.Q[3],EvaporateurMP.TwoPhaseFlowPipe.Q[2],EvaporateurMP.TwoPhaseFlowPipe.Q[1],EvaporateurMP.TwoPhaseFlowPipe.P[4],EvaporateurMP.TwoPhaseFlowPipe.P[3],EvaporateurMP.TwoPhaseFlowPipe.P[2],EvaporateurMP.ExchangerWall.Tp[3],EvaporateurMP.ExchangerWall.Tp[2],EvaporateurMP.ExchangerWall.Tp[1],BallonMP.Vl,BallonMP.Tp,BallonMP.hv,BallonMP.hl,BallonMP.P,SurchauffeurHP3.TwoPhaseFlowPipe.h[4],SurchauffeurHP3.TwoPhaseFlowPipe.h[3],SurchauffeurHP3.TwoPhaseFlowPipe.h[2],SurchauffeurHP3.TwoPhaseFlowPipe.Q[4],SurchauffeurHP3.TwoPhaseFlowPipe.Q[3],SurchauffeurHP3.TwoPhaseFlowPipe.Q[2],SurchauffeurHP3.TwoPhaseFlowPipe.P[4],SurchauffeurHP3.TwoPhaseFlowPipe.P[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[2],SurchauffeurHP3.ExchangerWall.Tp[3],SurchauffeurHP3.ExchangerWall.Tp[2],SurchauffeurHP3.ExchangerWall.Tp[1],SurchauffeurHP2.TwoPhaseFlowPipe.h[4],SurchauffeurHP2.TwoPhaseFlowPipe.h[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[2],SurchauffeurHP2.TwoPhaseFlowPipe.Q[4],SurchauffeurHP2.TwoPhaseFlowPipe.Q[3],SurchauffeurHP2.TwoPhaseFlowPipe.Q[2],SurchauffeurHP2.TwoPhaseFlowPipe.P[4],SurchauffeurHP2.TwoPhaseFlowPipe.P[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[2],SurchauffeurHP2.ExchangerWall.Tp[3],SurchauffeurHP2.ExchangerWall.Tp[2],SurchauffeurHP2.ExchangerWall.Tp[1],EconomiseurHP1.TwoPhaseFlowPipe.h[4],EconomiseurHP1.TwoPhaseFlowPipe.h[3],EconomiseurHP1.TwoPhaseFlowPipe.h[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[4],EconomiseurHP1.TwoPhaseFlowPipe.Q[3],EconomiseurHP1.TwoPhaseFlowPipe.Q[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[1],EconomiseurHP1.TwoPhaseFlowPipe.P[4],EconomiseurHP1.TwoPhaseFlowPipe.P[3],EconomiseurHP1.TwoPhaseFlowPipe.P[2],EconomiseurHP1.ExchangerWall.Tp[3],EconomiseurHP1.ExchangerWall.Tp[2],EconomiseurHP1.ExchangerWall.Tp[1],EconomiseurHP2.TwoPhaseFlowPipe.h[4],EconomiseurHP2.TwoPhaseFlowPipe.h[3],EconomiseurHP2.TwoPhaseFlowPipe.h[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[4],EconomiseurHP2.TwoPhaseFlowPipe.Q[3],EconomiseurHP2.TwoPhaseFlowPipe.Q[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[1],EconomiseurHP2.TwoPhaseFlowPipe.P[4],EconomiseurHP2.TwoPhaseFlowPipe.P[3],EconomiseurHP2.TwoPhaseFlowPipe.P[2],EconomiseurHP2.ExchangerWall.Tp[3],EconomiseurHP2.ExchangerWall.Tp[2],EconomiseurHP2.ExchangerWall.Tp[1],EconomiseurHP3.TwoPhaseFlowPipe.h[4],EconomiseurHP3.TwoPhaseFlowPipe.h[3],EconomiseurHP3.TwoPhaseFlowPipe.h[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[3],EconomiseurHP3.TwoPhaseFlowPipe.Q[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[1],EconomiseurHP3.TwoPhaseFlowPipe.P[4],EconomiseurHP3.TwoPhaseFlowPipe.P[3],EconomiseurHP3.TwoPhaseFlowPipe.P[2],EconomiseurHP3.ExchangerWall.Tp[3],EconomiseurHP3.ExchangerWall.Tp[2],EconomiseurHP3.ExchangerWall.Tp[1],SurchauffeurHP1.TwoPhaseFlowPipe.h[4],SurchauffeurHP1.TwoPhaseFlowPipe.h[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[4],SurchauffeurHP1.TwoPhaseFlowPipe.Q[3],SurchauffeurHP1.TwoPhaseFlowPipe.Q[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[1],SurchauffeurHP1.TwoPhaseFlowPipe.P[4],SurchauffeurHP1.TwoPhaseFlowPipe.P[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[2],SurchauffeurHP1.ExchangerWall.Tp[3],SurchauffeurHP1.ExchangerWall.Tp[2],SurchauffeurHP1.ExchangerWall.Tp[1],EconomiseurHP4.TwoPhaseFlowPipe.h[4],EconomiseurHP4.TwoPhaseFlowPipe.h[3],EconomiseurHP4.TwoPhaseFlowPipe.h[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[4],EconomiseurHP4.TwoPhaseFlowPipe.Q[3],EconomiseurHP4.TwoPhaseFlowPipe.Q[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[1],EconomiseurHP4.TwoPhaseFlowPipe.P[4],EconomiseurHP4.TwoPhaseFlowPipe.P[3],EconomiseurHP4.TwoPhaseFlowPipe.P[2],EconomiseurHP4.ExchangerWall.Tp[3],EconomiseurHP4.ExchangerWall.Tp[2],EconomiseurHP4.ExchangerWall.Tp[1],EvaporateurHP.TwoPhaseFlowPipe.h[4],EvaporateurHP.TwoPhaseFlowPipe.h[3],EvaporateurHP.TwoPhaseFlowPipe.h[2],EvaporateurHP.TwoPhaseFlowPipe.Q[4],EvaporateurHP.TwoPhaseFlowPipe.Q[3],EvaporateurHP.TwoPhaseFlowPipe.Q[2],EvaporateurHP.TwoPhaseFlowPipe.Q[1],EvaporateurHP.TwoPhaseFlowPipe.P[4],EvaporateurHP.TwoPhaseFlowPipe.P[3],EvaporateurHP.TwoPhaseFlowPipe.P[2],EvaporateurHP.ExchangerWall.Tp[3],EvaporateurHP.ExchangerWall.Tp[2],EvaporateurHP.ExchangerWall.Tp[1],VolumeEvapHP.h,BallonHP.Vl,BallonHP.Tp,BallonHP.hv,BallonHP.hl,BallonHP.P) * Number of discrete variables: 17 ($whenCondition1,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,perteChargeK2.C2.diff_on_1,vanne_extraction.C2.diff_on_1,CapteurDebitEauCondenseur.C1.diff_on_2,perteChargeK.C2.diff_on_2,Vanne_alimentationMPHP1.C2.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_2,EconomiseurMP.Cws1.diff_on_1,VolumeAlimMPHP.Cs1.diff_on_2) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (5210): * Single equations (assignments): 4801 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 256 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 4 * Torn equation systems: 142 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 4 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 55 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,2,100.0%), (1,2,100.0%), (1,2,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 87 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,5), (1,3), (2,8), (1,5), (1,3), (2,8), (1,5), (1,5), (1,3), (1,3), (48,433), (1,5), (1,3), (5,16), (1,5), (1,5), (1,2), (1,2), (4,18), (1,3), (1,4), (3,9), (1,4), (1,4)} Notification: Performance of Backend phase and start with SimCode phase: time 0.02628/14.58, allocations: 6.181 MB / 5.973 GB, free: 135.7 MB / 1.027 GB Notification: Performance of simCode: created initialization part: time 0.1552/14.73, allocations: 99.9 MB / 6.071 GB, free: 41.73 MB / 1.027 GB Notification: Performance of simCode: created event and clocks part: time 1.94e-05/14.73, allocations: 8 kB / 6.071 GB, free: 41.72 MB / 1.027 GB Notification: Performance of simCode: created simulation system equations: time 0.4181/15.15, allocations: 55.99 MB / 6.126 GB, free: 215.7 MB / 1.027 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.08126/15.23, allocations: 17.51 MB / 6.143 GB, free: 213.8 MB / 1.027 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.242/15.47, allocations: 132.6 MB / 6.272 GB, free: 172.8 MB / 1.027 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.01827/15.49, allocations: 13.75 MB / 6.286 GB, free: 171.2 MB / 1.027 GB Notification: Performance of simCode: alias equations: time 0.03878/15.53, allocations: 10.74 MB / 6.296 GB, free: 168.9 MB / 1.027 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.02503/15.56, allocations: 3.949 MB / 6.3 GB, free: 168.9 MB / 1.027 GB Notification: Performance of SimCode: time 1.823e-06/15.56, allocations: 0 / 6.3 GB, free: 168.9 MB / 1.027 GB Notification: Performance of Templates: time 2.577/18.13, allocations: 1.447 GB / 7.747 GB, free: 106.4 MB / 1.058 GB " [Timeout remaining time 642] make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.makefile [Timeout 660] (rm -f ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe >> ../files/ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.sim & ./ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC -abortSlowSimulation -alarm=240 -lv LOG_STATS > ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.pipe 2>&1) [Timeout 240] [Calling os._exit(0), Time elapsed: 65.95443288376555]