Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-08 numberOfIntervals=2500 stepSize=0.008 Regular simulation: ./ScalableTestSuite_noopt_ScalableTestSuite.Thermal.HeatExchanger.ScaledExperiments.CounterCurrentHeatExchangerEquations_N_10 -s=ida -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.000867461s reading init.xml | | | | | | 0.000101401s reading info.xml | | | | | | 0.00017593s [ 3.2%] pre-initialization | | | | | | 0.000219623s [ 4.0%] initialization | | | | | | 1.162e-06s [ 0.0%] steps | | | | | | 0.00122273s [ 22.2%] solver (excl. callbacks) | | | | | | 0.000492198s [ 9.0%] creating output-file | | | | | | 2.1079e-05s [ 0.4%] event-handling | | | | | | 0.000176334s [ 3.2%] overhead | | | | | | 0.00318986s [ 58.0%] simulation | | | | | | 0.00549892s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 401 steps taken | | | | | | 472 calls of functionODE | | | | | | 54 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000229842s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.