Environment - simulationEnvironment: startTime=0 stopTime=0.1 tolerance=1e-06 numberOfIntervals=500 stepSize=0.0002 Regular simulation: ./Modelica_4.0.0_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierBridge2mPulse.ThyristorBridge2mPulse_RL -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00822883s reading init.xml | | | | | | 0.000841021s reading info.xml | | | | | | 0.000388891s [ 1.2%] pre-initialization | | | | | | 0.000497435s [ 1.5%] initialization | | | | | | 0.000659018s [ 2.0%] steps | | | | | | 0.00180694s [ 5.4%] solver (excl. callbacks) | | | | | | 0.000356069s [ 1.1%] creating output-file | | | | | | 0.0179483s [ 53.2%] event-handling | | | | | | 9.7283e-05s [ 0.3%] overhead | | | | | | 0.0119599s [ 35.5%] simulation | | | | | | 0.0337139s [100.0%] total | | | | | events | | | | | | 89 state events | | | | | | 30 time events | | | | | solver: dassl | | | | | | 2617 steps taken | | | | | | 3236 calls of functionODE | | | | | | 1275 evaluations of jacobian | | | | | | 58 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0032646s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.