Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_12_Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.ConventionalWinter -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zonAHUOpt.sinZonFlo.ports[2].m_flow >= -1e5 and zonAHUOpt.sinZonFlo.ports[2].m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= zonAHUOpt.sinZonFlo.ports[2].m_flow <= 0.0, has value: 0.0509126" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zonAHUCon.sinZonFlo.ports[2].m_flow >= -1e5 and zonAHUCon.sinZonFlo.ports[2].m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= zonAHUCon.sinZonFlo.ports[2].m_flow <= 0.0, has value: 0.0509126" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 115200.000000 | | | | ((zonAHUOpt.hvac.cooCoi.m1_flow >= 0.0 and zonAHUOpt.hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= zonAHUOpt.hvac.cooCoi.m1_flow <= 1e5, has value: -2.29589e-41" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 547200.000000 | | | | ((zonAHUOpt.hvac.ideVal.preMasFlo.m_flow >= 0.0 and zonAHUOpt.hvac.ideVal.preMasFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= zonAHUOpt.hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -5.73972e-42" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.369028s reading init.xml | | | | | | 0.0316328s reading info.xml | | | | | | 0.00300063s [ 0.0%] pre-initialization | | | | | | 0.0519566s [ 0.8%] initialization | | | | | | 0.000764698s [ 0.0%] steps | | | | | | 0.109711s [ 1.7%] solver (excl. callbacks) | | | | | | 0.0113435s [ 0.2%] creating output-file | | | | | | 1.34078s [ 21.2%] event-handling | | | | | | 0.0236518s [ 0.4%] overhead | | | | | | 4.77909s [ 75.6%] simulation | | | | | | 6.32029s [100.0%] total | | | | | events | | | | | | 81 state events | | | | | | 8 time events | | | | | solver: dassl | | | | | | 6962 steps taken | | | | | | 9843 calls of functionODE | | | | | | 1499 evaluations of jacobian | | | | | | 403 error test failures | | | | | | 0 convergence test failures | | | | | | 3.46034s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.