Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Physiomodel_Physiomodel.Gases.IO_Bus.Gases_test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo): time 0.2069/0.2069, allocations: 17.46 MB / 36.81 MB, free: 6.789 MB / 33.03 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary master/package.mo): time 0.1957/0.1957, allocations: 17.95 MB / 64.44 MB, free: 8.812 MB / 58.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.00192/0.00192, allocations: 87.72 kB / 80.44 MB, free: 9.207 MB / 74.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002146/0.002146, allocations: 160 kB / 96.51 MB, free: 15.77 MB / 74.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.71/1.71, allocations: 177.1 MB / 289.6 MB, free: 6.254 MB / 234.7 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiomodel master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiomodel master/package.mo): time 0.82/0.82, allocations: 60.68 MB / 419.5 MB, free: 11.75 MB / 346.7 MB " [Timeout remaining time 179] Using package Physiomodel with version 1.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiomodel master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Using package Physiolibrary with version 3.1.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary master/package.mo) Using package Chemical with version 2.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo) Running command: translateModel(Physiomodel.Gases.IO_Bus.Gases_test,tolerance=1e-05,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Physiomodel_Physiomodel.Gases.IO_Bus.Gases_test") translateModel(Physiomodel.Gases.IO_Bus.Gases_test,tolerance=1e-05,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Physiomodel_Physiomodel.Gases.IO_Bus.Gases_test") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 2.315e-06/2.315e-06, allocations: 0 / 0.5136 GB, free: 1.789 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 4.187e-05/4.418e-05, allocations: 2.312 kB / 0.5136 GB, free: 1.785 MB / 442.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiomodel master/package.mo:18186:7-18186:41:writable] Error: Base class Physiolibrary.Types.IO_Bus not found in scope IO_Bus. Error: Class Physiomodel.Gases.IO_Bus.Gases_test not found in scope . Notification: Performance of FrontEnd: time 0.002201/0.002245, allocations: 0.7558 MB / 0.5143 GB, free: 1.031 MB / 442.7 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.9927030199905857]